Green Fluorescent Protein SELEX: Immobilization Chemistry and His‐Tag Epitope Bias

Abstract Despite numerous DNA aptamers for proteins having been reported, a model system allowing the use of cost‐effective proteins, unmodified DNA, and convenient homogeneous assays is still lacking, which has in turn limited not only fundamental studies of aptamers but also their translation to practical applications. Herein, three separate green fluorescent protein (GFP) selections were carried out using both non‐tagged and His‐tagged GFP immobilized on either NHS‐activated resin or Co 2+ affinity resin. Only the GFP/NHS system resulted in aptamers that consistently bind to unmodified GFP, whereas the His‐tagged GFP yielded aptamers biased toward the His‐tag epitope. Sequence alignment and fluorescence polarization assays indicate that many previously published aptamers bound to the His‐tag instead of the intended protein. This work not only obtained a model aptamer for proteins but also revealed critical information on bias toward His‐tags during aptamer selections.

Authors

Institutions

Publication Details

Journal
Angewandte Chemie
Published
2025-08-21
DOI
https://doi.org/10.1002/ange.202510518
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Green Fluorescent Protein SELEX: Immobilization Chemistry and His‐Tag Epitope Bias

Anthony J. Clarke, Stefen Stangherlin, Juewen Liu, Tyler Malloch
Angewandte Chemie
Advanced biosensing and bioanalysis techniques
article

Green Fluorescent Protein SELEX: Immobilization Chemistry and His‐Tag Epitope Bias

Anthony J. Clarke, Stefen Stangherlin, Juewen Liu, Tyler Malloch
article en

Abstract

Abstract Despite numerous DNA aptamers for proteins having been reported, a model system allowing the use of cost‐effective proteins, unmodified DNA, and convenient homogeneous assays is still lacking, which has in turn limited not only fundamental studies of aptamers but also their translation to practical applications. Herein, three separate green fluorescent protein (GFP) selections were carried out using both non‐tagged and His‐tagged GFP immobilized on either NHS‐activated resin or Co 2+ affinity resin. Only the GFP/NHS system resulted in aptamers that consistently bind to unmodified GFP, whereas the His‐tagged GFP yielded aptamers biased toward the His‐tag epitope. Sequence alignment and fluorescence polarization assays indicate that many previously published aptamers bound to the His‐tag instead of the intended protein. This work not only obtained a model aptamer for proteins but also revealed critical information on bias toward His‐tags during aptamer selections.

Angewandte Chemie
University of Waterloo (CA), University of Guelph (CA)
University of Waterloo, Natural Sciences and Engineering Research Council of Canada, Global Water Futures
Openalex Percentile: Top 81%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Green Fluorescent Protein SELEX: Immobilization Chemistry and His‐Tag Epitope Bias — Anthony J. Clarke, Stefen Stangherlin, et al. · Angewandte Chemie (2025) | TGRS Research Map | TGRS