A Retrospective Within-Subjects Analysis of Vancomycin Bayesian Modeling With Pre-steady-State vs Steady-State Concentrations
<b>Background:</b> Bayesian modeling of vancomycin can estimate 24-hour area under the curve (AUC<sub>24</sub>) using pre-steady-state concentrations. Limited literature exists comparing Bayesian AUC<sub>24</sub> calculations derived from steady-state versus pre-steady-state concentrations. <b>Objective:</b> To assess the agreement between vancomycin AUC<sub>24</sub> calculations using pre-steady-state versus steady-state concentrations, employing Bayesian modeling. <b>Methods:</b> This retrospective within-subjects cohort study included patients with at least 1 pre-steady-state and 1 steady-state vancomycin concentration. Patients with age >100 years, weight <40 kg, height <60 inches, or renal dysfunction were excluded. The steady-state AUC<sub>24</sub> from dosing software was documented with and without hiding steady-state levels from calculations. The primary outcome was agreement between AUC<sub>24</sub> without levels hidden compared with AUC<sub>24</sub> with steady-state levels hidden from analysis. Secondary outcomes included the agreement between AUC<sub>24</sub> with pre-steady-state levels hidden and the percentage of patients with matching AUC<sub>24</sub> categories. The AUC<sub>24</sub> agreement was evaluated via Bland-Altman plot and bias via linear regression. Statistical tests were performed using SPSS statistics software (IBM Corp). <b>Results:</b> A total of 93 patients were included. The mean difference in AUC<sub>24</sub> compared to AUC<sub>24</sub> with steady-state levels hidden was 8.8 mg*h/L, and with pre-steady-state levels hidden, it was -3.7 mg*h/L. Linear regression analysis indicated a proportional bias when steady-state levels were hidden (β = 0.22; <i>P</i> = 0.038) but not when pre-steady-state levels were hidden. Category mismatch occurred more often when steady-state levels were hidden vs when pre-steady-state levels were hidden (26% vs 8%; <i>P</i> < 0.001). <b>Conclusion and Relevance:</b> The study demonstrated overall agreement between AUC<sub>24</sub> compared to AUC<sub>24</sub> with steady-state levels hidden. The mean differences in AUC<sub>24</sub> estimates were small, no matter which level was hidden, although tighter limits of agreement were observed when steady-state levels were utilized in Bayesian calculations. Further research with larger sample sizes is necessary.
Authors
- Elizabeth W. Covington (ORCID: https://orcid.org/0000-0003-0082-6008)
- Sarah Grace Gunter
- Jihyun L. Chae
Institutions
- University of South Alabama Medical Center (US)
- Auburn University (US)
Publication Details
- Journal
- Journal of Pharmacy Technology
- Published
- 2025-08-21
- DOI
- https://doi.org/10.1177/87551225251362731
- Citations
- 1
- Primary Topic
- Antimicrobial Resistance in Staphylococcus
- Type
- article
- Field-Weighted Citation Impact
- 1.40