A rare case of instability and rod migration after C1–C2–C3–C4 screw fixation (clinical case and literature review)

Background. The rate of mechanical complications (screw system instability and hardware migration) associated with dorsal instrumental fixation of the cervical spine after injury ranges between 2 and 5 %. Implant migration, particularly of rods, following dorsal screw fixation of the cervical spine is a rare but potentially dangerous complication. Such complications can lead to severe neurological consequences and requires timely intervention. Aim. To analyze a clinical case of instability and migration of metal hardware following screw fixation of the C1–C2–C3–C4 segments in a patient with traumatic fractures of the C2 and C3 vertebra, and to review literature to identify risk factors and methods for preventing such complications. Material and methods. The study includes one clinical case of a patient who experienced complications – implant migration – after multilevel fixation of the cervical spine. Clinical examination, computed tomography (CT) were used to assess the condition of the patient and implants, along with a review of the literature on this issue. Results. The patient was diagnosed with instability of the metal hardware and migration of the rod into the posterior cranial fossa ( Fossa cranii posterior ) causing neurologic symptoms. A second surgical intervention was performed to remove the metal hardware. The literature review revealed that such cases are rare and require careful approach to selection of fixation methods and postoperative monitoring. Discussion. The analysis of the clinical case and the literature revealed possible causes of migration, including inadequate fixation and technical errors. Recommendations on prevention of such complications and patient management are proposed. Conclusion. Rare cases of instability and migration of the metal hardware following multilevel screw fixation of the cervical spine require personalized approach to diagnosis and treatment. Performing spinal fusion with strict adherence to surgical technique, increased awareness, and strict postoperative monitoring can reduce the risk of complications and improve treatment outcomes.

Authors

Institutions

Publication Details

Journal
Russian journal of neurosurgery
Published
2025-08-18
DOI
https://doi.org/10.63769/1683-3295-2025-27-2-120-129
Citations
1
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A rare case of instability and rod migration after C1–C2–C3–C4 screw fixation (clinical case and literature review)

I. E. Gritsaev, I. V. Basankin, P. B. Nesterenko, A. A. Giulzatyan et al.
1 citations
Russian journal of neurosurgery
Spinal Fractures and Fixation Techniques
2.01
article

A rare case of instability and rod migration after C1–C2–C3–C4 screw fixation (clinical case and literature review)

I. E. Gritsaev, I. V. Basankin, P. B. Nesterenko, A. A. Giulzatyan, В. А. Порханов, M. I. Tomina, K. K. Takhmazyan, S.B. Malakhov, E. R. Khurshudyan
article en
1 citations

Abstract

Background. The rate of mechanical complications (screw system instability and hardware migration) associated with dorsal instrumental fixation of the cervical spine after injury ranges between 2 and 5 %. Implant migration, particularly of rods, following dorsal screw fixation of the cervical spine is a rare but potentially dangerous complication. Such complications can lead to severe neurological consequences and requires timely intervention. Aim. To analyze a clinical case of instability and migration of metal hardware following screw fixation of the C1–C2–C3–C4 segments in a patient with traumatic fractures of the C2 and C3 vertebra, and to review literature to identify risk factors and methods for preventing such complications. Material and methods. The study includes one clinical case of a patient who experienced complications – implant migration – after multilevel fixation of the cervical spine. Clinical examination, computed tomography (CT) were used to assess the condition of the patient and implants, along with a review of the literature on this issue. Results. The patient was diagnosed with instability of the metal hardware and migration of the rod into the posterior cranial fossa ( Fossa cranii posterior ) causing neurologic symptoms. A second surgical intervention was performed to remove the metal hardware. The literature review revealed that such cases are rare and require careful approach to selection of fixation methods and postoperative monitoring. Discussion. The analysis of the clinical case and the literature revealed possible causes of migration, including inadequate fixation and technical errors. Recommendations on prevention of such complications and patient management are proposed. Conclusion. Rare cases of instability and migration of the metal hardware following multilevel screw fixation of the cervical spine require personalized approach to diagnosis and treatment. Performing spinal fusion with strict adherence to surgical technique, increased awareness, and strict postoperative monitoring can reduce the risk of complications and improve treatment outcomes.

Russian journal of neurosurgeryVol. 27(2)
Specialized Clinical Psychiatric Hospital No. 1 (RU)
Openalex Percentile: Top 12%
Spinal Fractures and Fixation Techniques
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.