Enhancing interventional cardiology training: a porcine heart-based coronary intervention simulator

Abstract Introduction Access to simulators for percutaneous coronary interventions is limited by cost and availability and is not part of most interventional fellowship programs. We developed a cost-effective coronary intervention simulator to enhance the training of interventionalists. Methods Porcine hearts from 6-month-old Yorkshire pigs (heart weight 300–500 g) were obtained from a large animal research laboratory. Guide catheters were inserted into the coronary artery ostia and secured with superglue. Polyurethane insulation foam was injected into the ventricles to maintain shape and rigidity. The guide catheter was then connected to a Tuohy valve connected to a 3-way stopcock. One connection led to a pressure infusion bag filled with tap water (inflated at > 300 mmHg); the other was used for contrast injection. The heart was set on a radiolucent box with a fluid collector underneath. Clinical scenarios were simulated using 3D-printed stenoses and occlusions, blood clots for occlusive myocardial infarction, balloon oversizing for dissections, and needle trauma for perforations. Results The simulator was used to practice managing perforations, bifurcation-stenting, dissections, and acute coronary occlusions. Assembly, setup, and simulation times until refilling were 50, 25, and 30 min, respectively. Intravascular imaging with Optical Coherence Tomography was successfully used to guide interventions. The simulator was frozen and reused three times without notable deterioration. Conclusion Our model can train a wide range of scenarios. The ability to be frozen for on-demand training enhances its utility. Limitations include the absence of pulsatile flow, heart movement, and the lack of guide catheter manipulation.

Authors

Institutions

Publication Details

Journal
Bulletin of the National Research Centre/Bulletin of the National Research Center
Published
2025-08-21
DOI
https://doi.org/10.1186/s42269-025-01341-3
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing interventional cardiology training: a porcine heart-based coronary intervention simulator

Jörg Reifart, Paul A. Iaizzo
Bulletin of the National Research Centre/Bulletin of the National Research Center
Surgical Simulation and Training
article

Enhancing interventional cardiology training: a porcine heart-based coronary intervention simulator

Jörg Reifart, Paul A. Iaizzo
article en

Abstract

Abstract Introduction Access to simulators for percutaneous coronary interventions is limited by cost and availability and is not part of most interventional fellowship programs. We developed a cost-effective coronary intervention simulator to enhance the training of interventionalists. Methods Porcine hearts from 6-month-old Yorkshire pigs (heart weight 300–500 g) were obtained from a large animal research laboratory. Guide catheters were inserted into the coronary artery ostia and secured with superglue. Polyurethane insulation foam was injected into the ventricles to maintain shape and rigidity. The guide catheter was then connected to a Tuohy valve connected to a 3-way stopcock. One connection led to a pressure infusion bag filled with tap water (inflated at > 300 mmHg); the other was used for contrast injection. The heart was set on a radiolucent box with a fluid collector underneath. Clinical scenarios were simulated using 3D-printed stenoses and occlusions, blood clots for occlusive myocardial infarction, balloon oversizing for dissections, and needle trauma for perforations. Results The simulator was used to practice managing perforations, bifurcation-stenting, dissections, and acute coronary occlusions. Assembly, setup, and simulation times until refilling were 50, 25, and 30 min, respectively. Intravascular imaging with Optical Coherence Tomography was successfully used to guide interventions. The simulator was frozen and reused three times without notable deterioration. Conclusion Our model can train a wide range of scenarios. The ability to be frozen for on-demand training enhances its utility. Limitations include the absence of pulsatile flow, heart movement, and the lack of guide catheter manipulation.

Bulletin of the National Research Centre/Bulletin of the National Research CenterVol. 49(1)
University of Minnesota (US), Mayo Clinic in Arizona (US)
Openalex Percentile: Top 65%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing interventional cardiology training: a porcine heart-based coronary intervention simulator — Jörg Reifart, Paul A. Iaizzo · Bulletin of the National Research Centre/Bulletin of the National Research Center (2025) | TGRS Research Map | TGRS