Development of Wireless Central Monitor Using X-bee Pro S2C (Electrocardiogram and Heart Rate)

Centralized monitoring of the condition of patients with serious conditions that are carried out continuously and in real-time is very important. in the development of previous researchers have some shortcomings, namely sending data still using cable, completeness of parameters that are still small, close delivery distance, not real-time, and continue. The purpose of this study is that the thick system is done wirelessly, more parameters, longer delivery distance, and can monitor electrocardiogram and heart rate in real-time and continue. the contribution of this research is that the wireless system can send ECG and bpm in real-time, long-distance, and continuously. To make deliveries in real-time, this study uses 2 transmitters and 2 receivers. Electrocardiogram signal obtained from tapping Lead II, then processed using a microcontroller circuit and the results in the form of a heart signal will be. Data is sent using X-Bee Pro. Data is displayed in the form of a patient's heart and BPM signals. In measuring BPM values ​​obtained error values ​​in module 1 0.1388% for BPM 240 and 0.093% for BPM 180, in module 2 0.1388% for BPM 240 and 0.185% for BPM 180, data transmission can be done well at a distance of 8 meters, 10 meters, and 25 meters with a barrier. The results of this study indicate that sending wirelessly can be done at a certain distance and in real-time. This research can be implemented in a central monitor in a hospital with more patients

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-20
DOI
https://doi.org/10.35882/ijeeemi.v2i1.256
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Wireless Central Monitor Using X-bee Pro S2C (Electrocardiogram and Heart Rate)

Bariroh Izzatul Ulumiddiniyah
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
ECG Monitoring and Analysis
article

Development of Wireless Central Monitor Using X-bee Pro S2C (Electrocardiogram and Heart Rate)

Bariroh Izzatul Ulumiddiniyah
article en

Abstract

Centralized monitoring of the condition of patients with serious conditions that are carried out continuously and in real-time is very important. in the development of previous researchers have some shortcomings, namely sending data still using cable, completeness of parameters that are still small, close delivery distance, not real-time, and continue. The purpose of this study is that the thick system is done wirelessly, more parameters, longer delivery distance, and can monitor electrocardiogram and heart rate in real-time and continue. the contribution of this research is that the wireless system can send ECG and bpm in real-time, long-distance, and continuously. To make deliveries in real-time, this study uses 2 transmitters and 2 receivers. Electrocardiogram signal obtained from tapping Lead II, then processed using a microcontroller circuit and the results in the form of a heart signal will be. Data is sent using X-Bee Pro. Data is displayed in the form of a patient's heart and BPM signals. In measuring BPM values ​​obtained error values ​​in module 1 0.1388% for BPM 240 and 0.093% for BPM 180, in module 2 0.1388% for BPM 240 and 0.185% for BPM 180, data transmission can be done well at a distance of 8 meters, 10 meters, and 25 meters with a barrier. The results of this study indicate that sending wirelessly can be done at a certain distance and in real-time. This research can be implemented in a central monitor in a hospital with more patients

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 2(1)
Politeknik Kesehatan Kemenkes Semarang (ID), Eskom (South Africa) (ZA)
Openalex Percentile: Top 66%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.