The Impact of Using Digital Filter and Analog Filter on EMG Signal

Many cases of accidents which resulted in humans having to surgery to save them, then performend muscle therapy to help the patient’s recovery after going through the post-surgery. This therapy has a purpose, so that the patient’s body is expected to return to normal. An exoskeleton is a tool like an additional clothing that aims not only to protect, but also to increase the wearer's abilities. Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles. The purpose of this study was to analyze the differences in the use of analog and digital filters on EMG, as well as the effect on the exoskeleton simulation. The method used in the main design consists of the myoware module, notch circuit, low pass filter, arduino uno, DAC module, teraterm software, and matlab. The intercepted signal is taken from the biceps using a disposable electrode (AG/AGCL.). The EMG signal tapped by the myoware module will continue to another circuit, then recorded on the Teraterm software, and analyzed in MATLAB. The voltage value on the analog filter is 1.541 Volt during relaxation and 2.086 Volt during contraction, while the digital filter that has passed through the DAC has a value of 41.8 mVolt during relaxation and 269.1 mVolt during contraction. The results of this study obtained that digital and analog filter values ​​have an average difference of 5 to 30. The conclusion of this research tool can detect changes in the use of analog and digital filters, in the future research can be developed by comparing other types of digital filters along with replacement to wireless systems. The benefit or purpose of this research is as a simulation of exoskeleton skeletal motion and can see the difference between the use of digital and analog filters

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-20
DOI
https://doi.org/10.35882/ijeeemi.v1i2.254
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Using Digital Filter and Analog Filter on EMG Signal

Endang Dian Setioningsih
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Muscle activation and electromyography studies
article

The Impact of Using Digital Filter and Analog Filter on EMG Signal

Endang Dian Setioningsih
article en

Abstract

Many cases of accidents which resulted in humans having to surgery to save them, then performend muscle therapy to help the patient’s recovery after going through the post-surgery. This therapy has a purpose, so that the patient’s body is expected to return to normal. An exoskeleton is a tool like an additional clothing that aims not only to protect, but also to increase the wearer's abilities. Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles. The purpose of this study was to analyze the differences in the use of analog and digital filters on EMG, as well as the effect on the exoskeleton simulation. The method used in the main design consists of the myoware module, notch circuit, low pass filter, arduino uno, DAC module, teraterm software, and matlab. The intercepted signal is taken from the biceps using a disposable electrode (AG/AGCL.). The EMG signal tapped by the myoware module will continue to another circuit, then recorded on the Teraterm software, and analyzed in MATLAB. The voltage value on the analog filter is 1.541 Volt during relaxation and 2.086 Volt during contraction, while the digital filter that has passed through the DAC has a value of 41.8 mVolt during relaxation and 269.1 mVolt during contraction. The results of this study obtained that digital and analog filter values ​​have an average difference of 5 to 30. The conclusion of this research tool can detect changes in the use of analog and digital filters, in the future research can be developed by comparing other types of digital filters along with replacement to wireless systems. The benefit or purpose of this research is as a simulation of exoskeleton skeletal motion and can see the difference between the use of digital and analog filters

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 1(2)
Politeknik Kesehatan Kemenkes Semarang (ID), Eskom (South Africa) (ZA)
Good health and well-being
Openalex Percentile: Top 80%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Impact of Using Digital Filter and Analog Filter on EMG Signal — Endang Dian Setioningsih · Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics (2025) | TGRS Research Map | TGRS