In Vivo Evaluation of Laser-Textured Air Plasma in Osseointegration of Dental Implants

The different macro and micro geometries of dental implants are parameters that directly affect osseointegration, making them an important area for research. The objective of this preclinical study was to compare, through histological and histomorphometric analyses, the biological response of two different dental implant surfaces in osseointegration. Surface morphology and chemistry were characterized by SEM/EDX, optical-emission spectroscopy, protein adsorption (BSA), and adipose-derived stem-cell morphology. For the in vivo arm, ten commercially pure titanium implants (n = 5 LS160 + 5 SBAE) were placed bilaterally in the tibiae of five skeletally mature New Zealand rabbits (one implant of each surface per animal). After six weeks, undecalcified sections were prepared and bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) were quantified histomorphometrically. Data normality was confirmed with the Shapiro-Wilk test; paired two-tailed Student's <i>t</i>-tests were applied (α = 0.05). Results: The descriptive histological analysis showed a fraction of pre-existing bone in all experimental groups, which probably ensured primary stability. Adjacent to this area, it was possible to observe peri-implant newformed bone in all tested groups. The results of the histomorphometric analysis of BIC and BAFO were considered normal by the Shapiro-Wilk test (<i>p</i> > 0.05); after six weeks of implantation, the BIC values for the LS160 and SBAE groups were 44.13 (15.83-72.43) and 39.24 (10.72-89.21), respectively. The analysis of variance (ANOVA and Tukey's post-test) showed no statistical differences between the groups tested. Likewise, the bone volume density showed no statistical differences between the groups (ANOVA and Tukey's post-test) with averages of 41.27 (C.I. 24.00-58.55) and 26.52 (C.I. -17.51-70.54) in the LS160 and SBAE groups, respectively. Although both surfaces showed similar osseointegration after six weeks, the new surface appears to be a promising, eco-friendly alternative to SBAE. Future studies with shorter time points and larger samples are needed to assess early biological responses.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-08-14
DOI
https://doi.org/10.3390/ma18163810
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vivo Evaluation of Laser-Textured Air Plasma in Osseointegration of Dental Implants

Federico Mussano, José Mauro Granjeiro, Mônica Diuana Calasans‐Maia, Suelen Cristina Sartoretto et al.
Materials
Dental Implant Techniques and Outcomes
article

In Vivo Evaluation of Laser-Textured Air Plasma in Osseointegration of Dental Implants

Federico Mussano, José Mauro Granjeiro, Mônica Diuana Calasans‐Maia, Suelen Cristina Sartoretto, F.V. Motta, Ezio Gheno, Rafael Seabra Louro, Domenico D’Angelo, Larissa Azeredo da Silva Lessa Nicolau, Olivio Della Bella, Pamella Santana Nunes
article en

Abstract

The different macro and micro geometries of dental implants are parameters that directly affect osseointegration, making them an important area for research. The objective of this preclinical study was to compare, through histological and histomorphometric analyses, the biological response of two different dental implant surfaces in osseointegration. Surface morphology and chemistry were characterized by SEM/EDX, optical-emission spectroscopy, protein adsorption (BSA), and adipose-derived stem-cell morphology. For the in vivo arm, ten commercially pure titanium implants (n = 5 LS160 + 5 SBAE) were placed bilaterally in the tibiae of five skeletally mature New Zealand rabbits (one implant of each surface per animal). After six weeks, undecalcified sections were prepared and bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) were quantified histomorphometrically. Data normality was confirmed with the Shapiro-Wilk test; paired two-tailed Student's <i>t</i>-tests were applied (α = 0.05). Results: The descriptive histological analysis showed a fraction of pre-existing bone in all experimental groups, which probably ensured primary stability. Adjacent to this area, it was possible to observe peri-implant newformed bone in all tested groups. The results of the histomorphometric analysis of BIC and BAFO were considered normal by the Shapiro-Wilk test (<i>p</i> > 0.05); after six weeks of implantation, the BIC values for the LS160 and SBAE groups were 44.13 (15.83-72.43) and 39.24 (10.72-89.21), respectively. The analysis of variance (ANOVA and Tukey's post-test) showed no statistical differences between the groups tested. Likewise, the bone volume density showed no statistical differences between the groups (ANOVA and Tukey's post-test) with averages of 41.27 (C.I. 24.00-58.55) and 26.52 (C.I. -17.51-70.54) in the LS160 and SBAE groups, respectively. Although both surfaces showed similar osseointegration after six weeks, the new surface appears to be a promising, eco-friendly alternative to SBAE. Future studies with shorter time points and larger samples are needed to assess early biological responses.

MaterialsVol. 18(16)
Universidade Federal Fluminense (BR), Instituto Nacional de Metrologia, Qualidade e Tecnologia (BR), Electrosonics Medical (US), Environment Park (IT), University of Turin (IT), University of Genoa (IT)
Openalex Percentile: Top 69%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.