Effect of Cs-Ion on the corrosion properties of implant materials

Ti-6Al-4V alloy produced by additive manufacturing method and Ti-6Al-4V alloy coated with BN ceramic were analyzed in SRIM/TRIM Monte Carlo Simulation program at 662 keV energy using parameters such as displacement, ionization and phonon, which provide information about radiation damage, using Cs-ion. Post-production coating thicknesses were determined by taking SEM images of the produced samples. As a result of coating the Ti-6Al-4V alloy with BN, the ion range decreased from the target depth of 3067 Å to 2447 Å. The total amount of damage to the material after coating decreased by approximately 21.1 % ensuring less phonon formation of the implant material exposed to the same gamma energy through the coating process, its negative effect on corrosion resistance, which is important in implant materials, is reduced.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2025-08-21
DOI
https://doi.org/10.1016/j.net.2025.103857
Citations
1
Primary Topic
Titanium Alloys Microstructure and Properties
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Cs-Ion on the corrosion properties of implant materials

Sema Bi̇lge Ocak, Uğur Gökmen, Zübeyde Özkan, İrem Balci et al.
1 citations
Nuclear Engineering and Technology
Titanium Alloys Microstructure and Properties
0.52
article

Effect of Cs-Ion on the corrosion properties of implant materials

Sema Bi̇lge Ocak, Uğur Gökmen, Zübeyde Özkan, İrem Balci, Murat Bi̇len
article en
1 citations

Abstract

Ti-6Al-4V alloy produced by additive manufacturing method and Ti-6Al-4V alloy coated with BN ceramic were analyzed in SRIM/TRIM Monte Carlo Simulation program at 662 keV energy using parameters such as displacement, ionization and phonon, which provide information about radiation damage, using Cs-ion. Post-production coating thicknesses were determined by taking SEM images of the produced samples. As a result of coating the Ti-6Al-4V alloy with BN, the ion range decreased from the target depth of 3067 Å to 2447 Å. The total amount of damage to the material after coating decreased by approximately 21.1 % ensuring less phonon formation of the implant material exposed to the same gamma energy through the coating process, its negative effect on corrosion resistance, which is important in implant materials, is reduced.

Nuclear Engineering and TechnologyVol. 57(12)
Turkish Armed Forces (TR), Sağlık Bilimleri Üniversitesi (TR), Gazi University (TR)
Openalex Percentile: Top 34%
Titanium Alloys Microstructure and Properties
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.