Coordinated overcurrent protection in distribution grids incorporating an active superconducting fault current limiter

The active saturated iron-core superconducting fault current limiter (SISFCL) is a promising technology for mitigating excessive fault currents in modern power distribution systems. This device is particularly valuable for integration into evolving smart grids, as it effectively suppresses fault currents during short-circuit events throughout the network. This paper offers a concise explanation of the SISFCL's working principles and its impedance behavior under fault conditions. The impact of integrating such a limiter on conventional inverse and fixed time-delay overcurrent protection schemes is examined. To ensure dependable protection performance in systems using SISFCLs, a method for coordinating protection settings is introduced. A model based on an actual 35 kV power distribution system with an integrated SISFCL was developed and evaluated using EMTDC/PSCAD software. The simulation outcomes confirm the soundness of the analytical framework. Index Terms—Active SFCL, saturated core, power distribution network, overcurrent relay, coordination, inverse-time protection.

Authors

Publication Details

Journal
Global Journal of Engineering and Technology Advances
Published
2025-08-20
DOI
https://doi.org/10.30574/gjeta.2025.24.2.0244
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coordinated overcurrent protection in distribution grids incorporating an active superconducting fault current limiter

Aland Faraidoon Ismael, A. J. Saber
Global Journal of Engineering and Technology Advances
HVDC Systems and Fault Protection
article

Coordinated overcurrent protection in distribution grids incorporating an active superconducting fault current limiter

Aland Faraidoon Ismael, A. J. Saber
article en

Abstract

The active saturated iron-core superconducting fault current limiter (SISFCL) is a promising technology for mitigating excessive fault currents in modern power distribution systems. This device is particularly valuable for integration into evolving smart grids, as it effectively suppresses fault currents during short-circuit events throughout the network. This paper offers a concise explanation of the SISFCL's working principles and its impedance behavior under fault conditions. The impact of integrating such a limiter on conventional inverse and fixed time-delay overcurrent protection schemes is examined. To ensure dependable protection performance in systems using SISFCLs, a method for coordinating protection settings is introduced. A model based on an actual 35 kV power distribution system with an integrated SISFCL was developed and evaluated using EMTDC/PSCAD software. The simulation outcomes confirm the soundness of the analytical framework. Index Terms—Active SFCL, saturated core, power distribution network, overcurrent relay, coordination, inverse-time protection.

Global Journal of Engineering and Technology AdvancesVol. 24(2)
Openalex Percentile: Top 80%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.