Behavior and design of short reinforced ultra-high performance concrete columns

Existing strength design framework for UHPC structural components has focused primarily on the flexural and shear design of UHPC beams. To further facilitate the deployment of UHPC within primary components (i.e., beams and columns), this study presents the component and section-level mechanics necessary for informing the strength design of UHPC columns. The existing strength design framework for UHPC components is explicitly extended to components subjected to axial-flexural and pure concentric axial loading. The extended design framework is evaluated for its accuracy and statistical robustness by comparing predicted strength values to the strength values of 79 experimental UHPC columns. Considerations for service and ultimate limit states are presented, with newly derived service limit states that account for the unique mechanical behavior of UHPC in compression as well as the statistical variations within the design framework. In addition, a simple effective lateral stiffness expression, which accounts for cracking, is developed to enable a more accurate estimation of load demands on axially loaded UHPC components. The results of this study highlight the high predictive performance of the extended design framework with mean predicted-to-experimental strength ratios of 0.96 and 1.00 for columns subject to axial-flexural and pure axial loading, respectively. Moreover, the influence of conventional confining reinforcement was found to be negligible on the strength prediction of columns under axial-flexural loading between axial load ratios of 4%–36%. However, conventional and fiber reinforcement ratios were found to influence the nominal axial strength capacity of columns under pure axial loading. Lastly, shortcomings and concerns within the extended design framework are discussed and highlighted. • A new database of 103 reinforced UHPC columns is compiled. • The influence of various design parameters on the mechanics of columns are elucidated. • The statistical robustness and accuracy of an extended design framework are quantified. • Newly derived service and ultimate limit states are presented. • A lateral stiffness expression is developed for estimating load demand on columns.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-08-20
DOI
https://doi.org/10.1016/j.engstruct.2025.121028
Citations
1
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behavior and design of short reinforced ultra-high performance concrete columns

JOSEPH A. ALMEIDA
1 citations
Engineering Structures
Structural Behavior of Reinforced Concrete
1.01
article

Behavior and design of short reinforced ultra-high performance concrete columns

JOSEPH A. ALMEIDA
article en
1 citations

Abstract

Existing strength design framework for UHPC structural components has focused primarily on the flexural and shear design of UHPC beams. To further facilitate the deployment of UHPC within primary components (i.e., beams and columns), this study presents the component and section-level mechanics necessary for informing the strength design of UHPC columns. The existing strength design framework for UHPC components is explicitly extended to components subjected to axial-flexural and pure concentric axial loading. The extended design framework is evaluated for its accuracy and statistical robustness by comparing predicted strength values to the strength values of 79 experimental UHPC columns. Considerations for service and ultimate limit states are presented, with newly derived service limit states that account for the unique mechanical behavior of UHPC in compression as well as the statistical variations within the design framework. In addition, a simple effective lateral stiffness expression, which accounts for cracking, is developed to enable a more accurate estimation of load demands on axially loaded UHPC components. The results of this study highlight the high predictive performance of the extended design framework with mean predicted-to-experimental strength ratios of 0.96 and 1.00 for columns subject to axial-flexural and pure axial loading, respectively. Moreover, the influence of conventional confining reinforcement was found to be negligible on the strength prediction of columns under axial-flexural loading between axial load ratios of 4%–36%. However, conventional and fiber reinforcement ratios were found to influence the nominal axial strength capacity of columns under pure axial loading. Lastly, shortcomings and concerns within the extended design framework are discussed and highlighted. • A new database of 103 reinforced UHPC columns is compiled. • The influence of various design parameters on the mechanics of columns are elucidated. • The statistical robustness and accuracy of an extended design framework are quantified. • Newly derived service and ultimate limit states are presented. • A lateral stiffness expression is developed for estimating load demand on columns.

Engineering StructuresVol. 343
New Jersey Institute of Technology (US)
National Science Foundation
Sustainable cities and communities
Openalex Percentile: Top 21%
Structural Behavior of Reinforced Concrete
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.