Progress in the Design of New Gas-Based Neutron Detectors: A Critical Review<i></i>

The detection of neutrons through gas detectors has been an established practice for decades, with significant applications in nuclear reactors and monitoring by international organizations responsible for safeguarding the use of nuclear energy. Historically, these detectors utilized Helium-3 (He-3) as the ionization gas due to its reliability, safety, ease of use, insensitivity to gamma radiation, and high efficiency in thermal neutron detection. However, the scarcity in the supply of He-3 has created an urgent need to develop new gas-based neutron detectors which do not rely on this isotope. Although significant technological advances have been made, challenges remain, particularly in improving the sensitivity and resolution of detectors and enhancing their ability to discriminate between neutrons and other forms of radiation, such as gamma radiation. In response to these demands, the present study aims to review recent advancements in the development of gas-based neutron detectors that can replace Helium-3-based detectors. The review focuses on the advantages of these new technologies, particularly in terms of neutron capture efficiency and linear response over a wide range of energies. This analysis was conducted through a critical review of the scientific literature, focusing on articles published in scientific journals between 2015 and 2024. The evolution of gas detectors is examined, from the technologies available in 2015 to the most recent innovations in gas neutron detectors. The findings highlight substantial improvements in detection efficiency and detector resolution, along with advances in particle discrimination. There is also a growing trend towards miniaturization of devices and the exploration of new doping techniques to increase sensitivity and reduce costs. It is concluded that, despite the significant advances achieved in the development of gas-based neutron detectors, there remains considerable room for further improvement. Areas such as device miniaturization, the use of new dopants, cost-benefit analysis, and the application of these detectors in new fields still offer substantial opportunities for innovation and development.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2025-08-20
DOI
https://doi.org/10.15392/2319-0612.2025.2893
Citations
2
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
3.77

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Progress in the Design of New Gas-Based Neutron Detectors: A Critical Review

Ary Machado de Azevedo, Wallace Vallory Nunes, Diogenes Kreusch Filho, Luan Lino Caetano
2 citations
Brazilian Journal of Radiation Sciences
Radiation Detection and Scintillator Technologies
3.77
article

Progress in the Design of New Gas-Based Neutron Detectors: A Critical Review

Ary Machado de Azevedo, Wallace Vallory Nunes, Diogenes Kreusch Filho, Luan Lino Caetano
article en
2 citations

Abstract

The detection of neutrons through gas detectors has been an established practice for decades, with significant applications in nuclear reactors and monitoring by international organizations responsible for safeguarding the use of nuclear energy. Historically, these detectors utilized Helium-3 (He-3) as the ionization gas due to its reliability, safety, ease of use, insensitivity to gamma radiation, and high efficiency in thermal neutron detection. However, the scarcity in the supply of He-3 has created an urgent need to develop new gas-based neutron detectors which do not rely on this isotope. Although significant technological advances have been made, challenges remain, particularly in improving the sensitivity and resolution of detectors and enhancing their ability to discriminate between neutrons and other forms of radiation, such as gamma radiation. In response to these demands, the present study aims to review recent advancements in the development of gas-based neutron detectors that can replace Helium-3-based detectors. The review focuses on the advantages of these new technologies, particularly in terms of neutron capture efficiency and linear response over a wide range of energies. This analysis was conducted through a critical review of the scientific literature, focusing on articles published in scientific journals between 2015 and 2024. The evolution of gas detectors is examined, from the technologies available in 2015 to the most recent innovations in gas neutron detectors. The findings highlight substantial improvements in detection efficiency and detector resolution, along with advances in particle discrimination. There is also a growing trend towards miniaturization of devices and the exploration of new doping techniques to increase sensitivity and reduce costs. It is concluded that, despite the significant advances achieved in the development of gas-based neutron detectors, there remains considerable room for further improvement. Areas such as device miniaturization, the use of new dopants, cost-benefit analysis, and the application of these detectors in new fields still offer substantial opportunities for innovation and development.

Brazilian Journal of Radiation SciencesVol. 13(3)
Military Institute of Engineering (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Openalex Percentile: Top 6%
Radiation Detection and Scintillator Technologies
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.