Miniaturized Dual-Band MIMO Implantable Antenna for IoMT-Enabled WCE and Deep Tissue Applications

Implantable devices play a vital role in IoT-based healthcare, creating the need for compact, multi-band antennas that support high data rates for biotelemetry. This study presents a miniaturized dual-band, dual-port MIMO implantable antenna designed for wireless capsule endoscopy (WCE) and deep tissue applications. The antenna is integrated within a capsule-type device and has compact dimensions of 11.5×6×0.6mm3. It operates in the Industrial, Scientific, and Medical (ISM) bands of 433.1–434.8 MHz and 902–928 MHz. The proposed antenna supports the transmission of high-quality images and video over a considerable distance. Miniaturization and high isolation are achieved using carefully designed meandered lines. This design avoids the use of shorting vias or ground-plane slots, which simplifies the structure and reduces back radiation. As a result, it eliminates the need for a complex decoupling network to enhance isolation. This antenna is the first reported MIMO implantable design to operate in the lower ISM bands while maintaining an ultra-compact size. Following a detailed simulation-based analysis, a prototype was fabricated. The measured results showed excellent agreement with simulations. The antenna provides impedance bandwidths of 61 MHz (466–405 MHz) and 112 MHz (846–958 MHz), and measured gains of –40.2 dBi and –35 dBi at 433 and 915 MHz, respectively. Specific absorption rate (SAR) analysis was conducted to ensure compliance with IEEE safety standards. A link margin study was also performed, demonstrating reliable communication for high data rates of 1, 78, and 120 Mbps, with a minimum coverage distance of 10 meters based on SAR constraints. To assess diversity performance, envelope correlation coefficient (ECC) and diversity gain (DG) were evaluated and found within acceptable limits. The antenna also exhibits pattern diversity at both operational bands. The proposed design offers a reliable and compact solution for high-data-rate, SAR-compliant biotelemetry in modern IoT-based healthcare systems.

Authors

Institutions

Publication Details

Journal
IEEE Internet of Things Journal
Published
2025-08-20
DOI
https://doi.org/10.1109/jiot.2025.3599186
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Miniaturized Dual-Band MIMO Implantable Antenna for IoMT-Enabled WCE and Deep Tissue Applications

Syed Manaf Ali Shah, Abdul Basir, Muhammad Zada, Sławomir Kozieł et al.
IEEE Internet of Things Journal
Wireless Body Area Networks
article

Miniaturized Dual-Band MIMO Implantable Antenna for IoMT-Enabled WCE and Deep Tissue Applications

Syed Manaf Ali Shah, Abdul Basir, Muhammad Zada, Sławomir Kozieł, Shahid Khan, Jamal Nasir, Ayesha Kanwal
article en

Abstract

Implantable devices play a vital role in IoT-based healthcare, creating the need for compact, multi-band antennas that support high data rates for biotelemetry. This study presents a miniaturized dual-band, dual-port MIMO implantable antenna designed for wireless capsule endoscopy (WCE) and deep tissue applications. The antenna is integrated within a capsule-type device and has compact dimensions of 11.5×6×0.6mm3. It operates in the Industrial, Scientific, and Medical (ISM) bands of 433.1–434.8 MHz and 902–928 MHz. The proposed antenna supports the transmission of high-quality images and video over a considerable distance. Miniaturization and high isolation are achieved using carefully designed meandered lines. This design avoids the use of shorting vias or ground-plane slots, which simplifies the structure and reduces back radiation. As a result, it eliminates the need for a complex decoupling network to enhance isolation. This antenna is the first reported MIMO implantable design to operate in the lower ISM bands while maintaining an ultra-compact size. Following a detailed simulation-based analysis, a prototype was fabricated. The measured results showed excellent agreement with simulations. The antenna provides impedance bandwidths of 61 MHz (466–405 MHz) and 112 MHz (846–958 MHz), and measured gains of –40.2 dBi and –35 dBi at 433 and 915 MHz, respectively. Specific absorption rate (SAR) analysis was conducted to ensure compliance with IEEE safety standards. A link margin study was also performed, demonstrating reliable communication for high data rates of 1, 78, and 120 Mbps, with a minimum coverage distance of 10 meters based on SAR constraints. To assess diversity performance, envelope correlation coefficient (ECC) and diversity gain (DG) were evaluated and found within acceptable limits. The antenna also exhibits pattern diversity at both operational bands. The proposed design offers a reliable and compact solution for high-data-rate, SAR-compliant biotelemetry in modern IoT-based healthcare systems.

IEEE Internet of Things JournalVol. 12(22)
COMSATS University Islamabad (PK), Tampere University (FI), Gdańsk University of Technology (PL), ETH Zurich (CH)
Affordable and clean energy
Openalex Percentile: Top 80%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.