Blood Glucose Anomaly Correction and Personalized Short-Term Prediction Based on Continuous Glucose Monitoring Data

Diabetes, as a chronic metabolic disease, relies on precise blood glucose monitoring and management for treatment. The quality of continuous glucose monitoring (CGM) data and prediction accuracy are critical for achieving closed-loop control in automated insulin delivery system (AIDS). To address challenges such as sensor anomalies and physiological delays in CGM data, this study proposes an attention-based framework for glucose anomaly detection and short-term prediction. First, we design an anomaly detection and correction module that integrates a multi-period spatiotemporal attention mechanism with a dual-task joint learning framework to simultaneously optimize anomaly identification and interpolation. Additionally, a blood glucose prediction module based on recurrent self-attention mechanism and transfer learning is proposed. Experimental results show that the proposed anomaly detection model achieves an accuracy of 96.4%, with Pearson correlation coefficients and intra-group correlation coefficients between interpolation results and actual values reaching 0.854 and 0.846, respectively. On the Yuwell dataset, the glucose prediction module attains an average RMSEs of 6.27, 10.40 and 14.31 mg/dL at 15, 30 and 45minutes.The average clinical safety zone coverage in Clarke error grid analysis reaches 99.52%. On the public OhioT1DM dataset, average clinical safety zone coverage of 98.92%. Our approach significantly outperforms some existing methods in detection sensitivity, prediction accuracy, and clinical applicability, providing a robust and practical solution for diabetes management.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-08-20
DOI
https://doi.org/10.1109/jsen.2025.3598254
Primary Topic
Artificial Intelligence in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blood Glucose Anomaly Correction and Personalized Short-Term Prediction Based on Continuous Glucose Monitoring Data

Zhigang Zhu, Zhichao Yu, Yutong Han, Zuo Jiang et al.
IEEE Sensors Journal
Artificial Intelligence in Healthcare
article

Blood Glucose Anomaly Correction and Personalized Short-Term Prediction Based on Continuous Glucose Monitoring Data

Zhigang Zhu, Zhichao Yu, Yutong Han, Zuo Jiang, Guanqun Zhang, Shufang Yuan
article en

Abstract

Diabetes, as a chronic metabolic disease, relies on precise blood glucose monitoring and management for treatment. The quality of continuous glucose monitoring (CGM) data and prediction accuracy are critical for achieving closed-loop control in automated insulin delivery system (AIDS). To address challenges such as sensor anomalies and physiological delays in CGM data, this study proposes an attention-based framework for glucose anomaly detection and short-term prediction. First, we design an anomaly detection and correction module that integrates a multi-period spatiotemporal attention mechanism with a dual-task joint learning framework to simultaneously optimize anomaly identification and interpolation. Additionally, a blood glucose prediction module based on recurrent self-attention mechanism and transfer learning is proposed. Experimental results show that the proposed anomaly detection model achieves an accuracy of 96.4%, with Pearson correlation coefficients and intra-group correlation coefficients between interpolation results and actual values reaching 0.854 and 0.846, respectively. On the Yuwell dataset, the glucose prediction module attains an average RMSEs of 6.27, 10.40 and 14.31 mg/dL at 15, 30 and 45minutes.The average clinical safety zone coverage in Clarke error grid analysis reaches 99.52%. On the public OhioT1DM dataset, average clinical safety zone coverage of 98.92%. Our approach significantly outperforms some existing methods in detection sensitivity, prediction accuracy, and clinical applicability, providing a robust and practical solution for diabetes management.

IEEE Sensors JournalVol. 25(19)
University of Shanghai for Science and Technology (CN), Danyang Hengan Chemical (China) (CN)
Zero hunger
Openalex Percentile: Top 76%
Artificial Intelligence in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.