Enhancing the Safety and Reliability of a Major Pipeline System With Main-Tie-Main, Arc-Flash, and Fast Bus Protection Schemes Using IEC 61850 Over a Software-Defined Network

The Trans-Alaska Pipeline System (TAPS) transports North Slope crude oil in Alaska from pump stations in Prudhoe Bay all the way to Valdez. The Valdez Marine Terminal is the northernmost ice-free port in North America, where tankers are loaded to deliver the critical crude oil supply to market. The Alyeska Pipeline Service Company, the operator of the TAPS, requires a reliable, safe, and redundant power supply for efficient and safe operation. Any electric power disruption and the associated downtime severely impacts the flow of oil through the pipeline and the loading of the tankers. The electric power reliability and safety is improved via a custom main-tie-main scheme, along with an arc-flash and fast bus protection scheme, using the high-speed IEC 61850 Generic Object-Oriented Substation Event protocol. This solution is also implemented with cybersecurity best practices that are resilient to external threats using a softwaredefined network supporting a zero-trust architecture and security gateways. This paper dives deeper into the objectives, design philosophy, communications architecture, and testing procedure for this solution. The scheme is standardized and successfully commissioned into service at Valdez Marine Terminal for one medium-voltage and two low-voltage switchgear facilities in 2019. This innovative solution is then scaled to include further switchgear facilities from 2019 to the present.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industry Applications
Published
2025-08-20
DOI
https://doi.org/10.1109/tia.2025.3601105
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the Safety and Reliability of a Major Pipeline System With Main-Tie-Main, Arc-Flash, and Fast Bus Protection Schemes Using IEC 61850 Over a Software-Defined Network

Donald L. Anderson, Tanushri Doshi, Kevin Lythgoe, Kenny Sheffler
IEEE Transactions on Industry Applications
Smart Grid Security and Resilience
article

Enhancing the Safety and Reliability of a Major Pipeline System With Main-Tie-Main, Arc-Flash, and Fast Bus Protection Schemes Using IEC 61850 Over a Software-Defined Network

Donald L. Anderson, Tanushri Doshi, Kevin Lythgoe, Kenny Sheffler
article en

Abstract

The Trans-Alaska Pipeline System (TAPS) transports North Slope crude oil in Alaska from pump stations in Prudhoe Bay all the way to Valdez. The Valdez Marine Terminal is the northernmost ice-free port in North America, where tankers are loaded to deliver the critical crude oil supply to market. The Alyeska Pipeline Service Company, the operator of the TAPS, requires a reliable, safe, and redundant power supply for efficient and safe operation. Any electric power disruption and the associated downtime severely impacts the flow of oil through the pipeline and the loading of the tankers. The electric power reliability and safety is improved via a custom main-tie-main scheme, along with an arc-flash and fast bus protection scheme, using the high-speed IEC 61850 Generic Object-Oriented Substation Event protocol. This solution is also implemented with cybersecurity best practices that are resilient to external threats using a softwaredefined network supporting a zero-trust architecture and security gateways. This paper dives deeper into the objectives, design philosophy, communications architecture, and testing procedure for this solution. The scheme is standardized and successfully commissioned into service at Valdez Marine Terminal for one medium-voltage and two low-voltage switchgear facilities in 2019. This innovative solution is then scaled to include further switchgear facilities from 2019 to the present.

IEEE Transactions on Industry ApplicationsVol. 62(2)
Schweizerisches Forschungsinstitut für Hochgebirgsklima und Medizin (CH), Albert Schweitzer Klinik (AT), AkzoNobel (Netherlands) (NL)
Openalex Percentile: Top 74%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing the Safety and Reliability of a Major Pipeline System With Main-Tie-Main, Arc-Flash, and Fast Bus Protection Schemes Using IEC 61850 Over a Software-Defined Network — Donald L. Anderson, Tanushri Doshi, et al. · IEEE Transactions on Industry Applications (2025) | TGRS Research Map | TGRS