Neural contrast sensitivity is not affected by myopic blur

The prevalence of myopia is increasing worldwide, accompanied by an increase of potentially under-corrected myopes. Because neural pathways are prone to adaptation in relation to the sensory input, we wondered to what extent neural contrast sensitivity (NCS) is altered in the presence of image blur arising from under-correction. No significant differences in NCS were observed between the three groups but were significantly equivalent between emmetropes, well-corrected, and under-corrected myopes (all p < 0.001). Across all healthy participants, NCS variability increased with increasing spatial frequency which could not be explained by variations in foveolar cone density. For an albinism patient, a large difference between the cut-off frequency and central cone density derived Nyquist sampling limit was observed. In conclusion, NCS is unaffected by myopia and remains stable for under-correction of up to 1.5 D. Furthermore, NCS testing can relate visual deficits to an underlying neurological disorder.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-08-20
DOI
https://doi.org/10.1038/s41598-025-15911-y
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Neural contrast sensitivity is not affected by myopic blur

Niklas Domdei, Julius Ameln, Jonas Müller, Wolf M. Harmening et al.
Scientific Reports
Ophthalmology and Visual Impairment Studies
article

Neural contrast sensitivity is not affected by myopic blur

Niklas Domdei, Julius Ameln, Jonas Müller, Wolf M. Harmening, Katharina Breher, Lisa Renner, Siegfried Wahl
article en

Abstract

The prevalence of myopia is increasing worldwide, accompanied by an increase of potentially under-corrected myopes. Because neural pathways are prone to adaptation in relation to the sensory input, we wondered to what extent neural contrast sensitivity (NCS) is altered in the presence of image blur arising from under-correction. No significant differences in NCS were observed between the three groups but were significantly equivalent between emmetropes, well-corrected, and under-corrected myopes (all p < 0.001). Across all healthy participants, NCS variability increased with increasing spatial frequency which could not be explained by variations in foveolar cone density. For an albinism patient, a large difference between the cut-off frequency and central cone density derived Nyquist sampling limit was observed. In conclusion, NCS is unaffected by myopia and remains stable for under-correction of up to 1.5 D. Furthermore, NCS testing can relate visual deficits to an underlying neurological disorder.

Scientific ReportsVol. 15(1)
Carl Zeiss (Germany) (DE), University of Bonn (DE), University Hospital Bonn (DE), Hochschule Aalen (DE), University of Tübingen (DE)
Deutsche Forschungsgemeinschaft, Eberhard Karls Universität Tübingen, Bundesministerium für Bildung und Forschung
Openalex Percentile: Top 70%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.