Post-therapeutic dosimetric evaluation of 166Ho radioembolization for liver malignancies: Impact of software on tumor and liver doses

Transarterial radioembolization using holmium-166 microspheres is a promising treatment for primary and secondary liver malignancies. Accurate post-therapeutic dosimetry is critical for optimizing outcomes, particularly in voxel-based dose assessment using quantitative single-photon emission computed tomography/ computed tomography (SPECT/CT). This study aimed to evaluate the impact of software choice and calibration method on absorbed dose estimates to the liver and tumor, by comparing two advanced dosimetry platforms: Hermia Voxel Dosimetry™ and Q-Suite™. Despite the recent discontinuation of 166Ho-microsphere production, such studies remain highly relevant given the global emphasis on personalized dosimetry, quantitative imaging in nuclear medicine, and potential applicability to other therapeutic radiopharmaceuticals and future microsphere technologies. Fourteen patients underwent a scout procedure, followed by therapy and post-treatment SPECT/CT imaging. Initial analysis revealed substantially lower mean liver and tumor doses with Hermia (12 ± 4 Gy and 58 ± 23 Gy) compared to Q-Suite (44 ± 9 Gy and 209 ± 83 Gy), with statistically significant differences (p=0.002 and p<0.001). Discrepancies were due to the gamma camera dead time and Hermia’s fixed calibration factor (CF). A patient-specific CF, derived from the camera’s response curve and administered activity, was applied to correct Hermia dose maps. The corrected doses, 42 ± 6 Gy and 196 ± 17 Gy, closely matched those from Q-Suite (p=0.69 and p=0.64). These findings underscore the critical role of system-specific calibration and acquisition timing in achieving accurate voxel-based dosimetry. Underestimation of absorbed doses may lead to suboptimal clinical decisions, including undertreatment or unrecognized toxicity. Thus, implementing patient-specific calibration protocols or equivalent corrections for dead time is essential to support safe, consistent, and effective radionuclide therapy in clinical practice.

Authors

Publication Details

Journal
Advances in Radiotherapy & Nuclear Medicine
Published
2025-08-18
DOI
https://doi.org/10.36922/arnm025220023
Primary Topic
Hepatocellular Carcinoma Treatment and Prognosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Post-therapeutic dosimetric evaluation of 166Ho radioembolization for liver malignancies: Impact of software on tumor and liver doses

Rita Albergueiro, Rafael Silva, João Santos
Advances in Radiotherapy & Nuclear Medicine
Hepatocellular Carcinoma Treatment and Prognosis
article

Post-therapeutic dosimetric evaluation of 166Ho radioembolization for liver malignancies: Impact of software on tumor and liver doses

Rita Albergueiro, Rafael Silva, João Santos
article en

Abstract

Transarterial radioembolization using holmium-166 microspheres is a promising treatment for primary and secondary liver malignancies. Accurate post-therapeutic dosimetry is critical for optimizing outcomes, particularly in voxel-based dose assessment using quantitative single-photon emission computed tomography/ computed tomography (SPECT/CT). This study aimed to evaluate the impact of software choice and calibration method on absorbed dose estimates to the liver and tumor, by comparing two advanced dosimetry platforms: Hermia Voxel Dosimetry™ and Q-Suite™. Despite the recent discontinuation of 166Ho-microsphere production, such studies remain highly relevant given the global emphasis on personalized dosimetry, quantitative imaging in nuclear medicine, and potential applicability to other therapeutic radiopharmaceuticals and future microsphere technologies. Fourteen patients underwent a scout procedure, followed by therapy and post-treatment SPECT/CT imaging. Initial analysis revealed substantially lower mean liver and tumor doses with Hermia (12 ± 4 Gy and 58 ± 23 Gy) compared to Q-Suite (44 ± 9 Gy and 209 ± 83 Gy), with statistically significant differences (p=0.002 and p<0.001). Discrepancies were due to the gamma camera dead time and Hermia’s fixed calibration factor (CF). A patient-specific CF, derived from the camera’s response curve and administered activity, was applied to correct Hermia dose maps. The corrected doses, 42 ± 6 Gy and 196 ± 17 Gy, closely matched those from Q-Suite (p=0.69 and p=0.64). These findings underscore the critical role of system-specific calibration and acquisition timing in achieving accurate voxel-based dosimetry. Underestimation of absorbed doses may lead to suboptimal clinical decisions, including undertreatment or unrecognized toxicity. Thus, implementing patient-specific calibration protocols or equivalent corrections for dead time is essential to support safe, consistent, and effective radionuclide therapy in clinical practice.

Advances in Radiotherapy & Nuclear MedicineVol. 3(3)
Openalex Percentile: Top 70%
Hepatocellular Carcinoma Treatment and Prognosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Post-therapeutic dosimetric evaluation of 166Ho radioembolization for liver malignancies: Impact of software on tumor and liver doses — Rita Albergueiro, Rafael Silva, et al. · Advances in Radiotherapy & Nuclear Medicine (2025) | TGRS Research Map | TGRS