Error in compression stress-strain curve recording without extensometer and its correction method for non-standard small-sized specimens

Compression tests employing small, non-standard specimens face challenges in accurate displacement measurement due to the unsuitability of contact extensometers and the high cost/complexity of video extensometers. The objective of this study is to develop a method for accurately measuring the true displacement of specimens during compression testing without the use of extensometers. Finite element analysis and compression tests on specimens with known elastic moduli identified three error components: frame deformation, contact gaps, and strain concentration at the fixture-specimen interface. Contact gaps can be eliminated through light preloading, leaving residual errors (denoted as Y) from frame compliance and interface strain concentration. Y was quantified by compressing small-diameter specimens of high-strength materials with known elastic moduli, specifically WC-11%Co cemented carbide, which was used in this study. The relationship between Y, load, and specimen diameter was established by subtracting the actual deformation of the small-diameter specimen from the total machine-recorded displacement. Subsequently, true specimen displacement was obtained by subtracting Y from the measured displacement. The method was validated on six metallic materials (Ni, W, Mo, Cu, Ti, #45 steel). Corrected stress-strain curves reduced elastic modulus errors to blow 10%. For example, Ni’s modulus improved from 26.5 GPa (uncorrected) to 195.4 GPa (96.7% of the true value), and W’s modulus increased from 34.2 to 370.2 GPa (92.6% of the true value). The proposed method requires only a single calibration test for specimens of identical diameter to establish Y-load-diameter mappings. Once integrated into testing systems, true displacement can be directly obtained, offering a cost-effective and operationally simple solution for small-specimen compression testing.

Authors

Institutions

Publication Details

Journal
The Journal of Strain Analysis for Engineering Design
Published
2025-08-20
DOI
https://doi.org/10.1177/03093247251356832
Citations
3
Primary Topic
High Entropy Alloys Studies
Type
article
Field-Weighted Citation Impact
2.14

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Error in compression stress-strain curve recording without extensometer and its correction method for non-standard small-sized specimens

Xueyang Zhou, Zhi Yang, Ruikang K. Wang, Tong Sun et al.
3 citations
The Journal of Strain Analysis for Engineering Design
High Entropy Alloys Studies
2.14
article

Error in compression stress-strain curve recording without extensometer and its correction method for non-standard small-sized specimens

Xueyang Zhou, Zhi Yang, Ruikang K. Wang, Tong Sun, Tingting Guo, Jinxiang Fang, Zhengming Xiao, Biao Ma, Haotian He
article en
3 citations

Abstract

Compression tests employing small, non-standard specimens face challenges in accurate displacement measurement due to the unsuitability of contact extensometers and the high cost/complexity of video extensometers. The objective of this study is to develop a method for accurately measuring the true displacement of specimens during compression testing without the use of extensometers. Finite element analysis and compression tests on specimens with known elastic moduli identified three error components: frame deformation, contact gaps, and strain concentration at the fixture-specimen interface. Contact gaps can be eliminated through light preloading, leaving residual errors (denoted as Y) from frame compliance and interface strain concentration. Y was quantified by compressing small-diameter specimens of high-strength materials with known elastic moduli, specifically WC-11%Co cemented carbide, which was used in this study. The relationship between Y, load, and specimen diameter was established by subtracting the actual deformation of the small-diameter specimen from the total machine-recorded displacement. Subsequently, true specimen displacement was obtained by subtracting Y from the measured displacement. The method was validated on six metallic materials (Ni, W, Mo, Cu, Ti, #45 steel). Corrected stress-strain curves reduced elastic modulus errors to blow 10%. For example, Ni’s modulus improved from 26.5 GPa (uncorrected) to 195.4 GPa (96.7% of the true value), and W’s modulus increased from 34.2 to 370.2 GPa (92.6% of the true value). The proposed method requires only a single calibration test for specimens of identical diameter to establish Y-load-diameter mappings. Once integrated into testing systems, true displacement can be directly obtained, offering a cost-effective and operationally simple solution for small-specimen compression testing.

The Journal of Strain Analysis for Engineering DesignVol. 61(1)
Kunming University of Science and Technology (CN), Yunnan University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 12%
High Entropy Alloys Studies
2.14
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.