Portable Real-Time Detection of Hydrogen Sulfide in Wastewater Using a Pt/CrWN<sub>2</sub>-Based Electrochemical Sensor

Efficient monitoring of hydrogen sulfide (H<sub>2</sub>S) in wastewater is essential for preventing environmental contamination and safeguarding public health. Current methods for assessing sulfide levels are limited by complex, time-consuming processes. Here, we introduce a Pt/CrWN<sub>2</sub>-based electrochemical gas sensor designed for real-time detection of H<sub>2</sub>S gas, offering a fast, reliable, and cost-effective solution for monitoring sulfate concentrations in wastewater. It exhibits rapid response and recovery times (3.6/3.5 s), high sensitivity (0.295 μA/ppm), and stability (90 days), even after direct exposure to sewage. Our findings demonstrate the potential of this system for continuous water quality assessment, providing valuable insights into pollution dynamics and enhancing environmental monitoring capabilities.

Authors

Institutions

Publication Details

Journal
Environmental Science & Technology
Published
2025-08-20
DOI
https://doi.org/10.1021/acs.est.5c03591
Citations
1
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable Real-Time Detection of Hydrogen Sulfide in Wastewater Using a Pt/CrWN2-Based Electrochemical Sensor

Huashuai Hu, Minghui Yang, Chenshuai Han, Zhaorui Zhang et al.
1 citations
Environmental Science & Technology
Advanced Chemical Sensor Technologies
0.67
article

Portable Real-Time Detection of Hydrogen Sulfide in Wastewater Using a Pt/CrWN2-Based Electrochemical Sensor

Huashuai Hu, Minghui Yang, Chenshuai Han, Zhaorui Zhang, Yu Liang, Chonghui Zhu
article en
1 citations

Abstract

Efficient monitoring of hydrogen sulfide (H<sub>2</sub>S) in wastewater is essential for preventing environmental contamination and safeguarding public health. Current methods for assessing sulfide levels are limited by complex, time-consuming processes. Here, we introduce a Pt/CrWN<sub>2</sub>-based electrochemical gas sensor designed for real-time detection of H<sub>2</sub>S gas, offering a fast, reliable, and cost-effective solution for monitoring sulfate concentrations in wastewater. It exhibits rapid response and recovery times (3.6/3.5 s), high sensitivity (0.295 μA/ppm), and stability (90 days), even after direct exposure to sewage. Our findings demonstrate the potential of this system for continuous water quality assessment, providing valuable insights into pollution dynamics and enhancing environmental monitoring capabilities.

Environmental Science & TechnologyVol. 59(34)
Dalian University of Technology (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Clean water and sanitation
Openalex Percentile: Top 28%
Advanced Chemical Sensor Technologies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Portable Real-Time Detection of Hydrogen Sulfide in Wastewater Using a Pt/CrWN<sub>2</sub>-Based Electrochemical Sensor — Huashuai Hu, Minghui Yang, et al. · Environmental Science & Technology (2025) | TGRS Research Map | TGRS