Assessing dose variability in PET/CT-based voxel dosimetry for Y-90 radioembolization

This study aimed to evaluate the impact of calculation parameters on organ dose coefficients in image-based dosimetry for Yttrium-90 (Y-90) transarterial radioembolization (TARE). Patient-specific dose coefficient maps were generated using PET/CT images from six hepatocellular carcinoma patients using TOPAS Monte Carlo simulations. To reduce spurious activity, PET values below varying thresholds (0, 50, and 100 kBq/mL) were excluded, and the effect of these thresholds on dose coefficients was assessed. The influence of CT Hounsfield unit conversion was examined by varying the number of materials from 1 to 24. The effects of dose calculation method, physics models, and voxel sizes on dose coefficients were systematically investigated. Spurious activity was the dominant factor influencing the variability of the dose coefficient. Adapting the activity threshold resulted in the mean difference of 38.8 (15.2 %), 3.3 (11.9 %), and 0.1 (6.5 %) Gy/GBq for the tumor, liver, and lungs. The mean difference of lung dose coefficient (1.1 Gy/GBq, 67.2 %) between single and 24 materials. The dose calculation method, physics model, and PET voxel size had a relatively small impact on variability. This study systematically evaluated potential factors contributing variability of dose coefficient after Y-90 TARE, with spurious activity identified as a major factor.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2025-08-20
DOI
https://doi.org/10.1016/j.net.2025.103856
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing dose variability in PET/CT-based voxel dosimetry for Y-90 radioembolization

Sangseok Ha, Wonmo Sung, Jieun Han, Seohan Kim et al.
Nuclear Engineering and Technology
Advanced Radiotherapy Techniques
article

Assessing dose variability in PET/CT-based voxel dosimetry for Y-90 radioembolization

Sangseok Ha, Wonmo Sung, Jieun Han, Seohan Kim, D. Y. Kang
article en

Abstract

This study aimed to evaluate the impact of calculation parameters on organ dose coefficients in image-based dosimetry for Yttrium-90 (Y-90) transarterial radioembolization (TARE). Patient-specific dose coefficient maps were generated using PET/CT images from six hepatocellular carcinoma patients using TOPAS Monte Carlo simulations. To reduce spurious activity, PET values below varying thresholds (0, 50, and 100 kBq/mL) were excluded, and the effect of these thresholds on dose coefficients was assessed. The influence of CT Hounsfield unit conversion was examined by varying the number of materials from 1 to 24. The effects of dose calculation method, physics models, and voxel sizes on dose coefficients were systematically investigated. Spurious activity was the dominant factor influencing the variability of the dose coefficient. Adapting the activity threshold resulted in the mean difference of 38.8 (15.2 %), 3.3 (11.9 %), and 0.1 (6.5 %) Gy/GBq for the tumor, liver, and lungs. The mean difference of lung dose coefficient (1.1 Gy/GBq, 67.2 %) between single and 24 materials. The dose calculation method, physics model, and PET voxel size had a relatively small impact on variability. This study systematically evaluated potential factors contributing variability of dose coefficient after Y-90 TARE, with spurious activity identified as a major factor.

Nuclear Engineering and TechnologyVol. 57(12)
Catholic Medical Center (US), Catholic University of Korea (KR)
National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 72%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessing dose variability in PET/CT-based voxel dosimetry for Y-90 radioembolization — Sangseok Ha, Wonmo Sung, et al. · Nuclear Engineering and Technology (2025) | TGRS Research Map | TGRS