Application of LSTM and GRU neural networks to improve peristaltic pump dosing accuracy

Peristaltic pumps (PP), widely acknowledged for their benefits in pharmaceutical contexts, face challenges in achieving optimal dosing accuracy. This investigation contributes novel insights for the improvement of dosing precision, identifying how to apply AI models, specifically focusing on Long Short-Term Memory (LSTM) and Gated Recurrent Unit (GRU) neural networks over a realistic span of target volumes. To provide a more accurate representation of real-world performance, we consider a modified root mean square error metric ( R M S E P P ) that directly compares dispensed volumes to target volumes. Based on this the study delves into two main methodologies: an iterative retraining method, called Online Training, and Pre-trained approach. Online Training shows best results, especially for volumes below 1.0 ml, achieving 38.4% improvement in R M S E P P and 31.6% in standard deviation ( S T D ). Pre-trained models are faster and exhibit promising outcomes especially for volumes above 1.0 ml, with a three-features approach delivering the best performance (13.8% and 4.6% improvements in R M S E P P and S T D , respectively). Overall, the findings highlight the effectiveness of iterative learning techniques, particularly for smaller dosage amounts, which complements the good performance of non-AI approaches for larger ones. • AI enhances peristaltic pump precision with adaptive run-time filling compensation. • GRU models excel in improving dosing accuracy for volumes under 1.0 ml. • Pre-trained approach shows potential, offering faster execution times. • Comprehensive comparison of AI and statistical methods across dosage ranges.

Authors

Institutions

Publication Details

Journal
Intelligent Systems with Applications
Published
2025-08-20
DOI
https://doi.org/10.1016/j.iswa.2025.200571
Citations
1
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of LSTM and GRU neural networks to improve peristaltic pump dosing accuracy

Sandro Bartolini, Stefano Bellissima, Davide Privitera
1 citations
Intelligent Systems with Applications
Hydraulic and Pneumatic Systems
0.71
article

Application of LSTM and GRU neural networks to improve peristaltic pump dosing accuracy

Sandro Bartolini, Stefano Bellissima, Davide Privitera
article en
1 citations

Abstract

Peristaltic pumps (PP), widely acknowledged for their benefits in pharmaceutical contexts, face challenges in achieving optimal dosing accuracy. This investigation contributes novel insights for the improvement of dosing precision, identifying how to apply AI models, specifically focusing on Long Short-Term Memory (LSTM) and Gated Recurrent Unit (GRU) neural networks over a realistic span of target volumes. To provide a more accurate representation of real-world performance, we consider a modified root mean square error metric ( R M S E P P ) that directly compares dispensed volumes to target volumes. Based on this the study delves into two main methodologies: an iterative retraining method, called Online Training, and Pre-trained approach. Online Training shows best results, especially for volumes below 1.0 ml, achieving 38.4% improvement in R M S E P P and 31.6% in standard deviation ( S T D ). Pre-trained models are faster and exhibit promising outcomes especially for volumes above 1.0 ml, with a three-features approach delivering the best performance (13.8% and 4.6% improvements in R M S E P P and S T D , respectively). Overall, the findings highlight the effectiveness of iterative learning techniques, particularly for smaller dosage amounts, which complements the good performance of non-AI approaches for larger ones. • AI enhances peristaltic pump precision with adaptive run-time filling compensation. • GRU models excel in improving dosing accuracy for volumes under 1.0 ml. • Pre-trained approach shows potential, offering faster execution times. • Comprehensive comparison of AI and statistical methods across dosage ranges.

Intelligent Systems with ApplicationsVol. 27
University of Siena (IT), Siena Biotech (Italy) (IT)
Affordable and clean energy
Openalex Percentile: Top 29%
Hydraulic and Pneumatic Systems
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.