Optimal Control of Iron Release in Drinking Water Distribution Systems Fed with Desalinated Water

When desalinated water enters the existing drinking water distribution systems (DWDSs), the balance between water and scale will be destroyed, resulting in the release of iron and water quality problems, causing “yellow water”. This study investigated the inhibitory effects of pH, alkalinity, and phosphate on iron release and the optimal control condition using pipe section reactors with a response surface. For steel pipe, the optimal condition for iron release control was pH = 8.5, alkalinity = 250 mg/L CaCO3, and phosphate = 0.1 mg/L. For cast iron pipe, the optimal condition was pH = 8.0, alkalinity = 250 mg/L CaCO3, and phosphate = 0.1 mg/L. This study can provide theoretical support for subsequent water supply safety and lay a foundation for the water supply safety of the municipal pipe network.

Authors

Institutions

Publication Details

Journal
Water
Published
2025-08-20
DOI
https://doi.org/10.3390/w17162474
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Control of Iron Release in Drinking Water Distribution Systems Fed with Desalinated Water

Jingyu Zhu, Tao Wan, Yanlong Ji, Yongjia Feng et al.
Water
Membrane Separation Technologies
article

Optimal Control of Iron Release in Drinking Water Distribution Systems Fed with Desalinated Water

Jingyu Zhu, Tao Wan, Yanlong Ji, Yongjia Feng, Peixin Jia, Mingzhou Fan, Hui Zhang
article en

Abstract

When desalinated water enters the existing drinking water distribution systems (DWDSs), the balance between water and scale will be destroyed, resulting in the release of iron and water quality problems, causing “yellow water”. This study investigated the inhibitory effects of pH, alkalinity, and phosphate on iron release and the optimal control condition using pipe section reactors with a response surface. For steel pipe, the optimal condition for iron release control was pH = 8.5, alkalinity = 250 mg/L CaCO3, and phosphate = 0.1 mg/L. For cast iron pipe, the optimal condition was pH = 8.0, alkalinity = 250 mg/L CaCO3, and phosphate = 0.1 mg/L. This study can provide theoretical support for subsequent water supply safety and lay a foundation for the water supply safety of the municipal pipe network.

WaterVol. 17(16)
Xi'an University of Architecture and Technology (CN)
Openalex Percentile: Top 80%
Membrane Separation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.