SIMULATION OF TEMPERATURE REGIME OF WATER-COOLED LOW-PRESSURE GAS MAGNETRON SYSTEM WITH INTERNAL MAGNET
Computer simulation, based on the principles of computational fluid dynamics, of the characteristics of indirect water cooling of a disk cooper magnetron target with a diameter of 50 mm and an integrated magnet is presented. With ion heating power of 100 W, the target heats up to 30…50°C, and the magnet heats up to less than 15°C, if water with a temperature of 10°C is supplied at a rate of 30…50 mm/s (or 150…250 cm3/min). The unevenness of the heating of the target is about one degree. This cooling mode and system can be recommended for use.
Authors
- A. I. Kuzmichev (ORCID: https://orcid.org/0000-0003-0087-275X)
- O.V. Bogdan
- S.O. Maykut
- Kh.S. Toyabina
Institutions
- National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute” (UA)
Publication Details
- Published
- 2025-08-07
- DOI
- https://doi.org/10.46813/2025-158-134
- Primary Topic
- Metal and Thin Film Mechanics
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Research Foundation of Ukraine
- National Research Foundation