A PDMS Coating-Based Balloon-Shaped Fiber Optic Respiratory Monitoring Sensor

A respiratory monitoring sensor based on a balloon-shaped optical fiber is proposed. The sensor consists of a single-mode fiber (SMF) coated with polydimethylsiloxane (PDMS) bent into a balloon shape to form a fiber optic Mach-Zehnder interferometer. The sensor's sensitivity to temperature enables monitoring of breathing status by recognizing the temperature changes that occur during human respiration. By adjusting the bending radius of the balloon-shaped SMF, high-order modes can be effectively excited to interfere with the core mode. Due to the high thermo-optic coefficient and thermal expansion coefficient of PDMS itself, the balloon-shaped fiber optic sensor can achieve temperature sensitivity. The experimental results show that the temperature sensitivity is -166.29 pm/°C in a temperature range of 30 °C to 60 °C. Finally, the proposed sensor was mounted into a respiratory mask to monitor different breathing states (normal, fast, slow, and oral-nasal breathing transitions) and breathing frequencies.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-08-20
DOI
https://doi.org/10.3390/s25165174
Citations
1
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A PDMS Coating-Based Balloon-Shaped Fiber Optic Respiratory Monitoring Sensor

Yu Zhang, Yunkun Cui, Jie Zhang, Qi Shi et al.
1 citations
Sensors
Advanced Fiber Optic Sensors
0.73
article

A PDMS Coating-Based Balloon-Shaped Fiber Optic Respiratory Monitoring Sensor

Yu Zhang, Yunkun Cui, Jie Zhang, Qi Shi, Feng Peng
article en
1 citations

Abstract

A respiratory monitoring sensor based on a balloon-shaped optical fiber is proposed. The sensor consists of a single-mode fiber (SMF) coated with polydimethylsiloxane (PDMS) bent into a balloon shape to form a fiber optic Mach-Zehnder interferometer. The sensor's sensitivity to temperature enables monitoring of breathing status by recognizing the temperature changes that occur during human respiration. By adjusting the bending radius of the balloon-shaped SMF, high-order modes can be effectively excited to interfere with the core mode. Due to the high thermo-optic coefficient and thermal expansion coefficient of PDMS itself, the balloon-shaped fiber optic sensor can achieve temperature sensitivity. The experimental results show that the temperature sensitivity is -166.29 pm/°C in a temperature range of 30 °C to 60 °C. Finally, the proposed sensor was mounted into a respiratory mask to monitor different breathing states (normal, fast, slow, and oral-nasal breathing transitions) and breathing frequencies.

SensorsVol. 25(16)
University of Jinan (CN), Taishan University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 24%
Advanced Fiber Optic Sensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.