An Open Source Validation System for Continuous Arterial Blood Pressure Measuring Sensors

The advancement of sensor technologies enables the measurement of high-quality continuous blood pressure signals, which has become an important area in healthcare. The development of such application-specific sensors can be time-consuming, expensive, and difficult to test or validate with known and consistent waveforms. In this manuscript, an open-source blood pressure waveform simulator with a Python validation package is described. The core part, a 3D-printed cam, can be generated based on real blood pressure waveforms. The validation software framework compares in detail the waveform used to design the cam with the time series from the sensor being validated. The simulator was validated using a 3D force sensor. The RMSE of accuracy was 1.94 (44)-2.74 (63)%, and the Pearson correlation with the nominal signal was 99.84 (13)-99.39 (18)%. As for precision, the RMSE of the repeatability of cam rotations was 1.53 (71)-2.13 (116)% and the Pearson correlation was 99.85 (16)-99.59 (57)%. The presented simulator proved to be robust and accurate in short- and long-term use, as it produced the signal waveform reliably and with high fidelity. It reduces development costs for early-stage sensor development and research, offering a solution that is easy to manufacture yet capable of continuously outputting human arterial blood pressure waveforms spanning multiple consecutive cardiac cycles.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-08-20
DOI
https://doi.org/10.3390/s25165173
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Open Source Validation System for Continuous Arterial Blood Pressure Measuring Sensors

Péter Sótonyi, Sándor Földi, György Cserey, Attila Répai
2 links
Sensors
Non-Invasive Vital Sign Monitoring
article

An Open Source Validation System for Continuous Arterial Blood Pressure Measuring Sensors

Péter Sótonyi, Sándor Földi, György Cserey, Attila Répai
article en

Abstract

The advancement of sensor technologies enables the measurement of high-quality continuous blood pressure signals, which has become an important area in healthcare. The development of such application-specific sensors can be time-consuming, expensive, and difficult to test or validate with known and consistent waveforms. In this manuscript, an open-source blood pressure waveform simulator with a Python validation package is described. The core part, a 3D-printed cam, can be generated based on real blood pressure waveforms. The validation software framework compares in detail the waveform used to design the cam with the time series from the sensor being validated. The simulator was validated using a 3D force sensor. The RMSE of accuracy was 1.94 (44)-2.74 (63)%, and the Pearson correlation with the nominal signal was 99.84 (13)-99.39 (18)%. As for precision, the RMSE of the repeatability of cam rotations was 1.53 (71)-2.13 (116)% and the Pearson correlation was 99.85 (16)-99.59 (57)%. The presented simulator proved to be robust and accurate in short- and long-term use, as it produced the signal waveform reliably and with high fidelity. It reduces development costs for early-stage sensor development and research, offering a solution that is easy to manufacture yet capable of continuously outputting human arterial blood pressure waveforms spanning multiple consecutive cardiac cycles.

SensorsVol. 25(16)
Semmelweis University (HU), Budapest University of Jewish Studies (HU), Pázmány Péter Catholic University (HU)
Nemzeti Kutatási, Fejlesztési és Innovaciós Alap
Openalex Percentile: Top 80%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.