Evaluation of Compatibility of Different Attachment Types Used in Orthodontic Clear Aligners with Electron Microscopy

<b>Background/Objectives</b>: The effectiveness of clear aligner therapy depends significantly on the precision of force delivery through the aligner-attachment interface. This study aimed to evaluate the microscopic compatibility between different orthodontic clear aligner materials (Duran+ and Zendura FLX) and attachment designs (rectangular and optimized) using scanning electron microscopy (SEM). <b>Methods</b>: Fifty-six samples were divided into four groups: rectangular attachments with Duran+ aligners (n = 14), rectangular attachments with Zendura FLX aligners (n = 14), optimized attachments with Duran+ aligners (n = 14), and optimized attachments with Zendura FLX aligners (n = 14). Attachments were bonded to bovine incisors using standardized protocols. Clear aligners were thermoformed at 220 °C for 40 s. Cross-sectional samples were analyzed using SEM at 250× magnification. Gap measurements were taken at seven points for rectangular attachments and five points for optimized attachments. <b>Results</b>: Gap measurements ranged from 14.75 ± 1.41 µm to 91.07 ± 3.11 µm. Zendura FLX demonstrated significantly better adaptation than Duran+ with rectangular attachments (42.10 ± 1.07 µm vs. 44.52 ± 1.51 µm, <i>p</i> < 0.001). Optimized attachments showed better overall adaptation than rectangular attachments. All combinations showed regional variation with the largest gaps at gingival borders (67.18-91.07 µm) and the smallest at flat buccal surfaces (14.75-20.98 µm). <b>Conclusions</b>: Perfect adaptation was not achieved with any material-attachment combination tested. Material selection and attachment design significantly influence microscopic adaptation, with multi-layer materials and optimized geometries showing superior performance. These findings provide mechanical explanations for clinical limitations in clear aligner therapy.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2025-08-20
DOI
https://doi.org/10.3390/dj13080379
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Compatibility of Different Attachment Types Used in Orthodontic Clear Aligners with Electron Microscopy

Can Arslan, Can Sever
Dentistry Journal
Orthodontics and Dentofacial Orthopedics
article

Evaluation of Compatibility of Different Attachment Types Used in Orthodontic Clear Aligners with Electron Microscopy

Can Arslan, Can Sever
article en

Abstract

<b>Background/Objectives</b>: The effectiveness of clear aligner therapy depends significantly on the precision of force delivery through the aligner-attachment interface. This study aimed to evaluate the microscopic compatibility between different orthodontic clear aligner materials (Duran+ and Zendura FLX) and attachment designs (rectangular and optimized) using scanning electron microscopy (SEM). <b>Methods</b>: Fifty-six samples were divided into four groups: rectangular attachments with Duran+ aligners (n = 14), rectangular attachments with Zendura FLX aligners (n = 14), optimized attachments with Duran+ aligners (n = 14), and optimized attachments with Zendura FLX aligners (n = 14). Attachments were bonded to bovine incisors using standardized protocols. Clear aligners were thermoformed at 220 °C for 40 s. Cross-sectional samples were analyzed using SEM at 250× magnification. Gap measurements were taken at seven points for rectangular attachments and five points for optimized attachments. <b>Results</b>: Gap measurements ranged from 14.75 ± 1.41 µm to 91.07 ± 3.11 µm. Zendura FLX demonstrated significantly better adaptation than Duran+ with rectangular attachments (42.10 ± 1.07 µm vs. 44.52 ± 1.51 µm, <i>p</i> < 0.001). Optimized attachments showed better overall adaptation than rectangular attachments. All combinations showed regional variation with the largest gaps at gingival borders (67.18-91.07 µm) and the smallest at flat buccal surfaces (14.75-20.98 µm). <b>Conclusions</b>: Perfect adaptation was not achieved with any material-attachment combination tested. Material selection and attachment design significantly influence microscopic adaptation, with multi-layer materials and optimized geometries showing superior performance. These findings provide mechanical explanations for clinical limitations in clear aligner therapy.

Dentistry JournalVol. 13(8)
Yeditepe University (TR)
Openalex Percentile: Top 77%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.