An X-ray beamline for utilizing intense, high-energy undulator radiation

The design, development and performance of an X-ray beamline for utilizing intense, high-energy undulator radiation are presented. A double multilayer monochromator, consisting of 150 pairs of 3.33 nm periodic Cr/C multilayers, provides intense X-rays by extracting a 1% energy bandwidth from high-order harmonic undulator radiation. We experimentally confirmed a high flux of 3.4 × 10<sup>13</sup> (1.3 × 10<sup>11</sup>) photons s<sup>-1</sup> with a beam size of 0.7 (0.3) mm (vertical) × 2.9 (∼4) mm (horizontal) at an X-ray energy of 100 (267) keV with a 1.0% (1.2%) energy bandwidth. Excellent performance of the high-energy high-flux X-ray beam was proven by conducting high-speed imaging analysis.

Authors

Institutions

Publication Details

Journal
Journal of Synchrotron Radiation
Published
2025-08-13
DOI
https://doi.org/10.1107/s1600577525006903
Citations
3
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
5.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An X-ray beamline for utilizing intense, high-energy undulator radiation

Taito Osaka, Hirokatsu Yumoto, Shunji Goto, Ichiro Inoue et al.
3 citations
Journal of Synchrotron Radiation
Advanced X-ray Imaging Techniques
5.65
article

An X-ray beamline for utilizing intense, high-energy undulator radiation

Taito Osaka, Hirokatsu Yumoto, Shunji Goto, Ichiro Inoue, Haruhiko Ohashi, Takahisa Koyama, Yasunori Senba, Yujiro Hayashi, Kenji Tamasaku, Makina Yabashi, Hiroshi Yamazaki
article en
3 citations

Abstract

The design, development and performance of an X-ray beamline for utilizing intense, high-energy undulator radiation are presented. A double multilayer monochromator, consisting of 150 pairs of 3.33 nm periodic Cr/C multilayers, provides intense X-rays by extracting a 1% energy bandwidth from high-order harmonic undulator radiation. We experimentally confirmed a high flux of 3.4 × 10<sup>13</sup> (1.3 × 10<sup>11</sup>) photons s<sup>-1</sup> with a beam size of 0.7 (0.3) mm (vertical) × 2.9 (∼4) mm (horizontal) at an X-ray energy of 100 (267) keV with a 1.0% (1.2%) energy bandwidth. Excellent performance of the high-energy high-flux X-ray beam was proven by conducting high-speed imaging analysis.

Journal of Synchrotron RadiationVol. 32(5)
SPring-8 (JP), Japan Synchrotron Radiation Research Institute (JP)
Affordable and clean energy
Openalex Percentile: Top 3%
Advanced X-ray Imaging Techniques
5.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.