INTEGRATED GEOPHYSICAL AND GEOTECHNICAL ANALYSIS TO SUBSURFACE LITHOLOGY OVERVIEW AT ITERA DORMITORY SITE, LAMPUNG, INDONESIA

The Student Dormitory is a gathering place for most new students at ITERA. For disaster mitigation, it is necessary to conduct geophysical and geotechnical surveys. Geophysical and geotechnical surveys are conducted to describe the subsurface lithology. The purpose of this study is to identify the subsurface of the Dormitory building so that it can be determined which buildings have the potential for geological hazards. The methods used are geomagnetic, geoelectric and geotechnical methods. The results obtained are that High and low magnetic anomalies are related to the thickness of the lithology. This is also justified by the results of geoelectric using resistivity cross-sections. The thickness of this lithology is related to the level of building security. TB4 has the highest security based on magnetic and geoelectric data. Meanwhile, TB1 has the lowest security based on subsurface conditions.

Authors

Institutions

Publication Details

Journal
Indonesian Physical Review
Published
2025-08-13
DOI
https://doi.org/10.29303/ipr.v8i3.488
Primary Topic
Geological and Geophysical Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INTEGRATED GEOPHYSICAL AND GEOTECHNICAL ANALYSIS TO SUBSURFACE LITHOLOGY OVERVIEW AT ITERA DORMITORY SITE, LAMPUNG, INDONESIA

Nono Agus Santoso, Syahidus Syuhada, Prastowo Adhi Irwanto
Indonesian Physical Review
Geological and Geophysical Studies
article

INTEGRATED GEOPHYSICAL AND GEOTECHNICAL ANALYSIS TO SUBSURFACE LITHOLOGY OVERVIEW AT ITERA DORMITORY SITE, LAMPUNG, INDONESIA

Nono Agus Santoso, Syahidus Syuhada, Prastowo Adhi Irwanto
article en

Abstract

The Student Dormitory is a gathering place for most new students at ITERA. For disaster mitigation, it is necessary to conduct geophysical and geotechnical surveys. Geophysical and geotechnical surveys are conducted to describe the subsurface lithology. The purpose of this study is to identify the subsurface of the Dormitory building so that it can be determined which buildings have the potential for geological hazards. The methods used are geomagnetic, geoelectric and geotechnical methods. The results obtained are that High and low magnetic anomalies are related to the thickness of the lithology. This is also justified by the results of geoelectric using resistivity cross-sections. The thickness of this lithology is related to the level of building security. TB4 has the highest security based on magnetic and geoelectric data. Meanwhile, TB1 has the lowest security based on subsurface conditions.

Indonesian Physical ReviewVol. 8(3)
Sumatera Institute of Technology (ID)
Openalex Percentile: Top 70%
Geological and Geophysical Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

INTEGRATED GEOPHYSICAL AND GEOTECHNICAL ANALYSIS TO SUBSURFACE LITHOLOGY OVERVIEW AT ITERA DORMITORY SITE, LAMPUNG, INDONESIA — Nono Agus Santoso, Syahidus Syuhada, et al. · Indonesian Physical Review (2025) | TGRS Research Map | TGRS