Measuring shoulder abduction strength using 2 different dynamometers: comprehensive intrarater and interrater reliability and validity

Objective: The purpose of this study is to investigate the intrarater and interrater reliability of handheld dynamometer (HHD) measurements in assessing isometric muscle strength of the shoulder abductors and to compare these results with those obtained using a fixed dynamometer (FD). Methods: The study involved 25 voluntary participants, all over the age of 18, asymptomatic (with no injuries in the upper extremity), and not engaged in overhead sports. The participants were evaluated twice by 2 di!erent testers who were experienced in orthopedic rehabilitation, at 90 degrees of shoulder abduction in the scapular plane. On the first measurement day, Tester 1 performed measurements using both HHD and FD, while on the second measurement day, both testers used only the HHD. A 3- to 7-day interval separated the 2 measurement sessions. Paired-samples t-tests were used to evaluate the systematic bias between the testers. Spearman's rank correlation coe"cient, intraclass correlation coe"cient, standard error of measurement, and minimal detectable change were calculated. The statistical significance level was accepted as P < .05. Results: Data from 22 participants (15 women, 7 men; mean age: 23.00 ± 3.19 years) were analyzed, as 3 individuals did not attend the final assessment. A strong correlation (r=0.772) was found between Tester 1's HHD measurements and FD, while a similarly strong correlation (r=0.748) was observed for Tester 2's HHD measurements. Excellent intrarater reliability (intraclass correlation coe"cient [ICC]=0.941) was found between Tester 1's measurements, and excellent interrater reliability (ICC=0.889) was found between testers. Conclusion: Handheld dynamometer has demonstrated excellent interrater and intrarater reliability and high validity for assessing shoulder abductor muscle strength in research and clinical use. Since the muscle strength of testers using the HHD may influence the results, the FD may be a more appropriate option when the study population is stronger than the testers. Studies involving di!erent clinical populations and testers with varying experience levels are needed to improve the relevance of the results. Level of Evidence: Level III, Diagnostic Study.

Authors

Institutions

Publication Details

Journal
Acta Orthopaedica et Traumatologica Turcica
Published
2025-08-13
DOI
https://doi.org/10.5152/j.aott.2025.25299
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measuring shoulder abduction strength using 2 different dynamometers: comprehensive intrarater and interrater reliability and validity

Arzu Razak Özdi̇nçler, Zeynep Hoşbay, Ecenur Atlı, Mahir Topaloğlu
Acta Orthopaedica et Traumatologica Turcica
Shoulder Injury and Treatment
article

Measuring shoulder abduction strength using 2 different dynamometers: comprehensive intrarater and interrater reliability and validity

Arzu Razak Özdi̇nçler, Zeynep Hoşbay, Ecenur Atlı, Mahir Topaloğlu
article en

Abstract

Objective: The purpose of this study is to investigate the intrarater and interrater reliability of handheld dynamometer (HHD) measurements in assessing isometric muscle strength of the shoulder abductors and to compare these results with those obtained using a fixed dynamometer (FD). Methods: The study involved 25 voluntary participants, all over the age of 18, asymptomatic (with no injuries in the upper extremity), and not engaged in overhead sports. The participants were evaluated twice by 2 di!erent testers who were experienced in orthopedic rehabilitation, at 90 degrees of shoulder abduction in the scapular plane. On the first measurement day, Tester 1 performed measurements using both HHD and FD, while on the second measurement day, both testers used only the HHD. A 3- to 7-day interval separated the 2 measurement sessions. Paired-samples t-tests were used to evaluate the systematic bias between the testers. Spearman's rank correlation coe"cient, intraclass correlation coe"cient, standard error of measurement, and minimal detectable change were calculated. The statistical significance level was accepted as P < .05. Results: Data from 22 participants (15 women, 7 men; mean age: 23.00 ± 3.19 years) were analyzed, as 3 individuals did not attend the final assessment. A strong correlation (r=0.772) was found between Tester 1's HHD measurements and FD, while a similarly strong correlation (r=0.748) was observed for Tester 2's HHD measurements. Excellent intrarater reliability (intraclass correlation coe"cient [ICC]=0.941) was found between Tester 1's measurements, and excellent interrater reliability (ICC=0.889) was found between testers. Conclusion: Handheld dynamometer has demonstrated excellent interrater and intrarater reliability and high validity for assessing shoulder abductor muscle strength in research and clinical use. Since the muscle strength of testers using the HHD may influence the results, the FD may be a more appropriate option when the study population is stronger than the testers. Studies involving di!erent clinical populations and testers with varying experience levels are needed to improve the relevance of the results. Level of Evidence: Level III, Diagnostic Study.

Acta Orthopaedica et Traumatologica TurcicaVol. 59(5)
Koç University (TR), Fenerbahçe University (TR), Biruni University (TR)
Affordable and clean energy
Openalex Percentile: Top 65%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.