Dosimetric characterization of a p-n silicon carbide detector under 320 kV X-ray irradiation

Abstract This work presents the comprehensive dosimetric characterization of a p-n silicon carbide (SiC) detector exposed to a 320 kV p X-ray beam, with the aim of evaluating its potential for preclinical and translational medical applications. The detector, based on a 10 μm thick 4H-SiC epitaxial layer, was assessed in terms of linearity with absorbed dose, dose rate dependence, percentage depth dose (PDD) distribution, response variation with field size, and short- and long-term reproducibility. Results demonstrated a highly linear dose-response relationship and negligible dose-rate dependence over the investigated range. The SiC device exhibited a consistent performance across different field sizes and penetration depths, highlighting its suitability for accurate dosimetry under medium-energy X-ray irradiation. Given its wide bandgap, low leakage current, high radiation tolerance, and near-tissue equivalence, the characterized SiC detector appears as a promising alternative to conventional dosimetric systems for radiobiological experiments and preclinical quality assurance in intermediate energy photon beams.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-08-01
DOI
https://doi.org/10.1088/1748-0221/20/08/c08019
Citations
2
Primary Topic
Radiation Effects in Electronics
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric characterization of a p-n silicon carbide detector under 320 kV X-ray irradiation

Mariacristina Guarrera, C. Verona, Giada Petringa, Vincenzo Salamone et al.
2 citations
Journal of Instrumentation
Radiation Effects in Electronics
1.46
article

Dosimetric characterization of a p-n silicon carbide detector under 320 kV X-ray irradiation

Mariacristina Guarrera, C. Verona, Giada Petringa, Vincenzo Salamone, S. Tudisco, Roberto Catalano, G. Cuttone, G.A.P. Cirrone, A. Kurmanova, L. Raffaele
article en
2 citations

Abstract

Abstract This work presents the comprehensive dosimetric characterization of a p-n silicon carbide (SiC) detector exposed to a 320 kV p X-ray beam, with the aim of evaluating its potential for preclinical and translational medical applications. The detector, based on a 10 μm thick 4H-SiC epitaxial layer, was assessed in terms of linearity with absorbed dose, dose rate dependence, percentage depth dose (PDD) distribution, response variation with field size, and short- and long-term reproducibility. Results demonstrated a highly linear dose-response relationship and negligible dose-rate dependence over the investigated range. The SiC device exhibited a consistent performance across different field sizes and penetration depths, highlighting its suitability for accurate dosimetry under medium-energy X-ray irradiation. Given its wide bandgap, low leakage current, high radiation tolerance, and near-tissue equivalence, the characterized SiC detector appears as a promising alternative to conventional dosimetric systems for radiobiological experiments and preclinical quality assurance in intermediate energy photon beams.

Journal of InstrumentationVol. 20(08)
University of Rome Tor Vergata (IT), University of Catania (IT), Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud (IT)
Openalex Percentile: Top 16%
Radiation Effects in Electronics
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.