Effect of Conductivity on Beat Frequency Detection in Chirp Pulse Transmission Imaging

Permittivity estimation using chirp pulse transmission imaging (CPTI) is a novel method that requires further investigation to fully understand the effects of different parameters on its accuracy. This paper specifically examines the influence of conductivity on the detection of the beat frequency corresponding to the direct path through the object, a key factor that directly impacts the accuracy of permittivity estimation. The results demonstrate that, while the estimation equation is independent of conductivity, conductivity does affect the magnitude of the mixed signal in the frequency domain. These findings highlight the robustness of chirp pulse transmission imaging approach for accurate permittivity estimation across varying conductive environments.

Authors

Institutions

Publication Details

Published
2025-07-20
DOI
https://doi.org/10.1109/antem64578.2025.11114312
Primary Topic
Earthquake Detection and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Conductivity on Beat Frequency Detection in Chirp Pulse Transmission Imaging

Zahra Lasemiimeni, Elise Fear
Earthquake Detection and Analysis
article

Effect of Conductivity on Beat Frequency Detection in Chirp Pulse Transmission Imaging

Zahra Lasemiimeni, Elise Fear
article en

Abstract

Permittivity estimation using chirp pulse transmission imaging (CPTI) is a novel method that requires further investigation to fully understand the effects of different parameters on its accuracy. This paper specifically examines the influence of conductivity on the detection of the beat frequency corresponding to the direct path through the object, a key factor that directly impacts the accuracy of permittivity estimation. The results demonstrate that, while the estimation equation is independent of conductivity, conductivity does affect the magnitude of the mixed signal in the frequency domain. These findings highlight the robustness of chirp pulse transmission imaging approach for accurate permittivity estimation across varying conductive environments.

University of Calgary (CA)
Alberta Cancer Foundation, Natural Sciences and Engineering Research Council of Canada
Affordable and clean energy
Openalex Percentile: Top 78%
Earthquake Detection and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Conductivity on Beat Frequency Detection in Chirp Pulse Transmission Imaging — Zahra Lasemiimeni, Elise Fear · (2025) | TGRS Research Map | TGRS