The Effect of Microfabricated Cell Adhesion Areas on Ultrasound Response of Ion Channel-Type Receptor

These days, an ion channel-type receptor called TRP A 1 has been found to increase intracellular <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{Ca}^{2+}$</tex> concentration in response to ultrasound. However, the ultrasound response characteristics of TRP A 1 remain largely uncharacterized, particularly regarding the effect of cell adhesion on the ultrasound response of TRP A 1. Here, we evaluated the effect of microfabricated cellular adhesion areas on ultrasound responsiveness using micropatterning techniques. The ultrasound responsiveness of cells was examined at the center and periphery of each four pattern shapes. Across all pattern shapes, cells at the periphery showed a faster ultrasound response compared to those at the center. Moreover, in small pattern areas, TRP Al showed a greater response to ultrasound stimulation compared to larger pattern areas. In conclusion, these results indicate that the ultrasound response depends on the stress that occurs for the cell.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/transducers61432.2025.11109513
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Microfabricated Cell Adhesion Areas on Ultrasound Response of Ion Channel-Type Receptor

S. Koda, Shigenori Miura, Yuta Kurashina, Lisa Mitsuda
Acoustic Wave Resonator Technologies
article

The Effect of Microfabricated Cell Adhesion Areas on Ultrasound Response of Ion Channel-Type Receptor

S. Koda, Shigenori Miura, Yuta Kurashina, Lisa Mitsuda
article en

Abstract

These days, an ion channel-type receptor called TRP A 1 has been found to increase intracellular <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{Ca}^{2+}$</tex> concentration in response to ultrasound. However, the ultrasound response characteristics of TRP A 1 remain largely uncharacterized, particularly regarding the effect of cell adhesion on the ultrasound response of TRP A 1. Here, we evaluated the effect of microfabricated cellular adhesion areas on ultrasound responsiveness using micropatterning techniques. The ultrasound responsiveness of cells was examined at the center and periphery of each four pattern shapes. Across all pattern shapes, cells at the periphery showed a faster ultrasound response compared to those at the center. Moreover, in small pattern areas, TRP Al showed a greater response to ultrasound stimulation compared to larger pattern areas. In conclusion, these results indicate that the ultrasound response depends on the stress that occurs for the cell.

Hiroshima University of Economics (JP), Tokyo University of Agriculture and Technology (JP)
Openalex Percentile: Top 80%
Acoustic Wave Resonator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.