Sustained AC Plasma Generation at Low Voltage Using a Miniaturized High-Q Rosen Transformer

This work presents the design and experimental results for a suspended bulk lithium niobate Rosen-type piezoelectric transformer capable of generating stable, nonthermal atmospheric plasma with an input power as low as 33 mW. The piezoelectric transformer, optimized using COMSOL Multiphysics, achieved an unloaded quality factor of 4,370 in air, and a voltage gain sufficient for plasma onset at 2.69 V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">RMS</inf>. Thermal imaging confirmed that the plasma remained near ambient temperature throughout operation, demonstrating the nonthermal nature of the discharge. These results mark a significant reduction in required power compared to prior studies and establish a foundation for low-power plasma applications.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/transducers61432.2025.11111219
Citations
1
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sustained AC Plasma Generation at Low Voltage Using a Miniaturized High-Q Rosen Transformer

Reza Abdolvand, Justin Phelps
1 citations
Plasma Diagnostics and Applications
0.73
article

Sustained AC Plasma Generation at Low Voltage Using a Miniaturized High-Q Rosen Transformer

Reza Abdolvand, Justin Phelps
article en
1 citations

Abstract

This work presents the design and experimental results for a suspended bulk lithium niobate Rosen-type piezoelectric transformer capable of generating stable, nonthermal atmospheric plasma with an input power as low as 33 mW. The piezoelectric transformer, optimized using COMSOL Multiphysics, achieved an unloaded quality factor of 4,370 in air, and a voltage gain sufficient for plasma onset at 2.69 V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">RMS</inf>. Thermal imaging confirmed that the plasma remained near ambient temperature throughout operation, demonstrating the nonthermal nature of the discharge. These results mark a significant reduction in required power compared to prior studies and establish a foundation for low-power plasma applications.

University of Central Florida (US)
Affordable and clean energy
Openalex Percentile: Top 25%
Plasma Diagnostics and Applications
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sustained AC Plasma Generation at Low Voltage Using a Miniaturized High-Q Rosen Transformer — Reza Abdolvand, Justin Phelps · (2025) | TGRS Research Map | TGRS