Smart Stent for Real-Time Endoleak Detection

While minimally invasive endovascular aneurysm repair (EVAR) is effective, an inevitable risk of leaking (called Endoleak) remains. To detect Endoleak, we present a Smart Stent platform using a piezoelectric thin film wrapped on a 3D-printed nylon scaffold, enabling real-time pressure and flow sensing. Experimental results show that the Smart Stent output reaches 186.8 m V at systolic pressure (119.9 mmHg), measured using artificial abdominal aortic aneurysm (AAA) models. Endoleaks are detected by monitoring variations in the Smart Stent baseline. The Smart Stent baseline is decreased by 65.2% (65.01 mV) under Endoleak type I, while Endoleak type III decreased it by 77.5% (43.35 mV) compared to the stable condition, i.e., no-Endoleak (186.8 mV). These results demonstrate the potential of Smart Stent technologies for precise hemodynamic monitoring.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/transducers61432.2025.11111050
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smart Stent for Real-Time Endoleak Detection

Trisha Das Mou, Albert Kim, Jun Ying Tan, Subhrodeep Ray et al.
Aortic aneurysm repair treatments
article

Smart Stent for Real-Time Endoleak Detection

Trisha Das Mou, Albert Kim, Jun Ying Tan, Subhrodeep Ray, Haijun Liu, Jungkwun ‘JK’ Kim
article en

Abstract

While minimally invasive endovascular aneurysm repair (EVAR) is effective, an inevitable risk of leaking (called Endoleak) remains. To detect Endoleak, we present a Smart Stent platform using a piezoelectric thin film wrapped on a 3D-printed nylon scaffold, enabling real-time pressure and flow sensing. Experimental results show that the Smart Stent output reaches 186.8 m V at systolic pressure (119.9 mmHg), measured using artificial abdominal aortic aneurysm (AAA) models. Endoleaks are detected by monitoring variations in the Smart Stent baseline. The Smart Stent baseline is decreased by 65.2% (65.01 mV) under Endoleak type I, while Endoleak type III decreased it by 77.5% (43.35 mV) compared to the stable condition, i.e., no-Endoleak (186.8 mV). These results demonstrate the potential of Smart Stent technologies for precise hemodynamic monitoring.

University of North Texas (US), University of South Florida (US), University of South Florida St. Petersburg (US), Temple University (US)
National Science Foundation
Openalex Percentile: Top 68%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.