Stretchable Microneedle Array Electrode for Movement-Resistant Electroencephalogram Monitoring

To achieve long-term stable electroencephalogram (EEG) acquisition, avoiding motion-induced unstable contact between electrodes and skin is important. This work introduces a stretchable microneedle array (SMNA) electrode for movement-resistant EEG recording. The SMNA consists of a rigid epoxy microneedle array and an intrinsically stretchable styrene-ethylene-butylene-styrene (SEBS) substrate. The hard microneedles can penetrate the stratum corneum to realize low contact impedance, while the stretchable substrate can closely fit the curved scalp and adapt to the movement of the skin, reducing electrode displacement and detachment caused by movement. SMNA electrodes are assembled with customized polyurethane stretchable circuit boards to obtain 32-channel SMNA electrode patches, which enable 8 hours of high-quality EEG signal recording. After the long-term EEG monitoring, there was no skin damage, and the imprint left by the microneedles could be restored within 20 minutes.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/transducers61432.2025.11111546
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stretchable Microneedle Array Electrode for Movement-Resistant Electroencephalogram Monitoring

Junshi Li, Zhitong Zhang, Jiayan Zhang, Zhihong Li et al.
EEG and Brain-Computer Interfaces
article

Stretchable Microneedle Array Electrode for Movement-Resistant Electroencephalogram Monitoring

Junshi Li, Zhitong Zhang, Jiayan Zhang, Zhihong Li, Y. B. Zhao
article en

Abstract

To achieve long-term stable electroencephalogram (EEG) acquisition, avoiding motion-induced unstable contact between electrodes and skin is important. This work introduces a stretchable microneedle array (SMNA) electrode for movement-resistant EEG recording. The SMNA consists of a rigid epoxy microneedle array and an intrinsically stretchable styrene-ethylene-butylene-styrene (SEBS) substrate. The hard microneedles can penetrate the stratum corneum to realize low contact impedance, while the stretchable substrate can closely fit the curved scalp and adapt to the movement of the skin, reducing electrode displacement and detachment caused by movement. SMNA electrodes are assembled with customized polyurethane stretchable circuit boards to obtain 32-channel SMNA electrode patches, which enable 8 hours of high-quality EEG signal recording. After the long-term EEG monitoring, there was no skin damage, and the imprint left by the microneedles could be restored within 20 minutes.

Peking University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 79%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Stretchable Microneedle Array Electrode for Movement-Resistant Electroencephalogram Monitoring — Junshi Li, Zhitong Zhang, et al. · (2025) | TGRS Research Map | TGRS