A Novel Multi-Aperture-Distribution Based Cold Cathode Driven Plasma Assisted BWO

We introduce a novel multi-aperture r-θ configuration on a plasma assisted cold cathode to generate a high current density electron beam simultaneously with high energy and high fill factor. The generation of an electron beam with all three characteristics is a critical challenge in designing an electron beam source for efficient RF generation from BWO. The optimization of the beam emitting apertures distribution is carried out using 3D PIC software, VSim. An electron beam source based on the cold cathode optimized design with 17 circular apertures of dia 1 mm each is developed. The developed electron beam source is utilized inside the plasma assisted BWO. The efficiency of the cold cathode-driven BWO is found to be 16.5 % with an RF peak power of 12 kW at an applied gap voltage of ~20 kV. The measured frequency of the generated RF radiation is ranging from 10-11.75 GHz.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.1109/ivec63678.2025.11115785
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Multi-Aperture-Distribution Based Cold Cathode Driven Plasma Assisted BWO

Niraj Kumar, Prerna Unadkat
Plasma Diagnostics and Applications
article

A Novel Multi-Aperture-Distribution Based Cold Cathode Driven Plasma Assisted BWO

Niraj Kumar, Prerna Unadkat
article en

Abstract

We introduce a novel multi-aperture r-θ configuration on a plasma assisted cold cathode to generate a high current density electron beam simultaneously with high energy and high fill factor. The generation of an electron beam with all three characteristics is a critical challenge in designing an electron beam source for efficient RF generation from BWO. The optimization of the beam emitting apertures distribution is carried out using 3D PIC software, VSim. An electron beam source based on the cold cathode optimized design with 17 circular apertures of dia 1 mm each is developed. The developed electron beam source is utilized inside the plasma assisted BWO. The efficiency of the cold cathode-driven BWO is found to be 16.5 % with an RF peak power of 12 kW at an applied gap voltage of ~20 kV. The measured frequency of the generated RF radiation is ranging from 10-11.75 GHz.

Central Electronics Engineering Research Institute (IN)
Affordable and clean energy
Openalex Percentile: Top 80%
Plasma Diagnostics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.