Wearable Microneedle-Integrated Distance-Based Paper Device for Transdermal Cortisol and Dopamine Monitoring

This study introduces a wearable microneedle-distance-based paper analytical device (MN-dPAD) for simultaneous transdermal detection of cortisol and dopamine. Through the integration of a biocompatible hydrogel microneedle array with a wax-printed paper device, the device facilitates the minimally invasive sampling of interstitial fluid (ISF) and visual quantification of analytes. Cortisol and dopamine are detected via oxidation-reduction reactions, exhibiting detection limits of 0.25 μg mL<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> and 1.0 ng mL<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>, respectively, with high precision and recovery studies. Compared with existing techniques, MN -dP AD offers user accessibility, simplicity, cost-effectiveness, and does not require complex instruments, thereby presenting a promising tool for point-of-care (POC) testing for stress and its related disorders.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/transducers61432.2025.11110776
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable Microneedle-Integrated Distance-Based Paper Device for Transdermal Cortisol and Dopamine Monitoring

Danilo M. dos Santos, Sameer Sonkusale, Kawin Khachornsakkula
Advancements in Transdermal Drug Delivery
article

Wearable Microneedle-Integrated Distance-Based Paper Device for Transdermal Cortisol and Dopamine Monitoring

Danilo M. dos Santos, Sameer Sonkusale, Kawin Khachornsakkula
article en

Abstract

This study introduces a wearable microneedle-distance-based paper analytical device (MN-dPAD) for simultaneous transdermal detection of cortisol and dopamine. Through the integration of a biocompatible hydrogel microneedle array with a wax-printed paper device, the device facilitates the minimally invasive sampling of interstitial fluid (ISF) and visual quantification of analytes. Cortisol and dopamine are detected via oxidation-reduction reactions, exhibiting detection limits of 0.25 μg mL<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> and 1.0 ng mL<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>, respectively, with high precision and recovery studies. Compared with existing techniques, MN -dP AD offers user accessibility, simplicity, cost-effectiveness, and does not require complex instruments, thereby presenting a promising tool for point-of-care (POC) testing for stress and its related disorders.

Tufts University (US)
National Science Foundation
Affordable and clean energy
Openalex Percentile: Top 84%
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Wearable Microneedle-Integrated Distance-Based Paper Device for Transdermal Cortisol and Dopamine Monitoring — Danilo M. dos Santos, Sameer Sonkusale, et al. · (2025) | TGRS Research Map | TGRS