Corrosion Protection of Magnetoelastic Sensors for Enhancing Lifetime in Wirelessly Interrogated Biliary Stents
This paper reports on corrosion protection coatings for wireless magnetoelastic resonant sensors for implantable devices, with biliary stent monitoring as initial target. It reports coatings that allow the sensor lifetime in bile solution to exceed the patency duration of plastic biliary stents; it also reports the quantitative variation in sensor response that is attributable to corrosion. Thin film coatings of Al<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>, HfO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>, multilayer HfO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>/Al<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>, and Al<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>/Parylene are compared for their impact on the resonant frequency, quality factor and signal strength of sensors in biliary fluid. The multilayer HfO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>/Al<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf> coating maintains a detectable sensor signal for over 168 days with minimal signal degradation. The Al<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>/Parylene coating extends the detectable period to over 230 days despite degradation in signal strength. The shifts in resonant frequency and quality factor over this duration are correlated to the exposure time for potential use in compensating sensor response.
Authors
- Yogesh B. Gianchandani (ORCID: https://orcid.org/0000-0003-2281-3937)
- Zeyu Li (ORCID: https://orcid.org/0009-0005-2947-0043)
- Ramprasad M. Nambisan (ORCID: https://orcid.org/0000-0002-8674-0856)
Institutions
- Integrated Nonclinical Development Solutions (United States) (US)
Publication Details
- Published
- 2025-06-29
- DOI
- https://doi.org/10.1109/transducers61432.2025.11111086
- Primary Topic
- Non-Destructive Testing Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00