Gear Train-Enabled Low-Power Thermomechanical Biopsy System for Ingestible Capsules

This paper reports the first successful demonstration of a gear train-enabled low-power thermomechanical biopsy system for ingestible capsules. The biopsy module utilizes a torque-loaded 3D-printed gear train and collection tool to scrape the GI mucosa to be stored in the capsule body. Actuation is triggered by a microfabricated thin film heater using 36–42 mA of instantaneous current draw and a power of 138 mW. The module produced 1.6±0.7 N (mean ± SEM, n=5) of force to collect a sample volume of 19±8.0 mg from agarose tissue phantoms. Sample volumes collected are compatible with polymerase chain reaction (PCR) for genetic biomarker detection. The device's low-power operation allows integration with onboard electronics, activation by a single ingestible-sized battery, and the future development of a wireless ingestible capsule for tissue sampling.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/transducers61432.2025.11111615
Primary Topic
Renal function and acid-base balance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gear Train-Enabled Low-Power Thermomechanical Biopsy System for Ingestible Capsules

Joshua A. Levy, P. A. Sweeney, Michael A. Straker, Reza Ghodssi
Renal function and acid-base balance
article

Gear Train-Enabled Low-Power Thermomechanical Biopsy System for Ingestible Capsules

Joshua A. Levy, P. A. Sweeney, Michael A. Straker, Reza Ghodssi
article en

Abstract

This paper reports the first successful demonstration of a gear train-enabled low-power thermomechanical biopsy system for ingestible capsules. The biopsy module utilizes a torque-loaded 3D-printed gear train and collection tool to scrape the GI mucosa to be stored in the capsule body. Actuation is triggered by a microfabricated thin film heater using 36–42 mA of instantaneous current draw and a power of 138 mW. The module produced 1.6±0.7 N (mean ± SEM, n=5) of force to collect a sample volume of 19±8.0 mg from agarose tissue phantoms. Sample volumes collected are compatible with polymerase chain reaction (PCR) for genetic biomarker detection. The device's low-power operation allows integration with onboard electronics, activation by a single ingestible-sized battery, and the future development of a wireless ingestible capsule for tissue sampling.

Bioengineering Center (RU)
Affordable and clean energy
Openalex Percentile: Top 77%
Renal function and acid-base balance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.