Simultaneous Wireless Power and Data Transfer to Biomedical Implants via Series-Resonant Capacitive Links

This paper investigates the performance of series-resonant capacitive links for simultaneous wireless power and data transfer to biomedical implants. A novel method leveraging balanced signals and geometrical symmetry in capacitive plates arrangement is proposed to reduce the interference between the two separate power and data links by ~ 22 dB, enabling reliable simultaneous operation. The proposed technique is validated through simulations and ex vivo measurements with a 2.5 mm-thick beef tissue slice, where the data link operates at 12.5 MHz and the power link at 8.3 MHz. The proposed link configuration achieves a measured maximum power transfer efficiency (PTE) of 58.6% and power delivered to the load (PDL) of 83.6 mW for the power link. The data link achieves a high data rate of 25 Mbps with a bit error rate (BER) of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$&lt; 10^{-3}$</tex>.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/transducers61432.2025.11111508
Citations
1
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Wireless Power and Data Transfer to Biomedical Implants via Series-Resonant Capacitive Links

Hossein Miri Lavasani, Pedram Mohseni, Hossein Yaghobi, Mohammad Mobaraki
1 citations
Wireless Power Transfer Systems
0.73
article

Simultaneous Wireless Power and Data Transfer to Biomedical Implants via Series-Resonant Capacitive Links

Hossein Miri Lavasani, Pedram Mohseni, Hossein Yaghobi, Mohammad Mobaraki
article en
1 citations

Abstract

This paper investigates the performance of series-resonant capacitive links for simultaneous wireless power and data transfer to biomedical implants. A novel method leveraging balanced signals and geometrical symmetry in capacitive plates arrangement is proposed to reduce the interference between the two separate power and data links by ~ 22 dB, enabling reliable simultaneous operation. The proposed technique is validated through simulations and ex vivo measurements with a 2.5 mm-thick beef tissue slice, where the data link operates at 12.5 MHz and the power link at 8.3 MHz. The proposed link configuration achieves a measured maximum power transfer efficiency (PTE) of 58.6% and power delivered to the load (PDL) of 83.6 mW for the power link. The data link achieves a high data rate of 25 Mbps with a bit error rate (BER) of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$&lt; 10^{-3}$</tex>.

Case Western Reserve University (US)
Affordable and clean energy
Openalex Percentile: Top 25%
Wireless Power Transfer Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.