Low-Cost Lead-Ion Imprinted Polymer Membrane Microfluidic Sensor for Selective Trace Lead Monitoring in Water

This study introduces an innovative electrochemical micro fluidic sensor incorporating a stand-alone Lead-ion Imprinted Polymer (Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>+_IIP) membrane for highly selective and trace lead ion detection in water. Unlike conventional sensors, this design embeds the Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>+ - lIP membrane between two in-situ fabricated conductive electrodes within a microfluidic device, enabling direct analyte-membrane interactions for enhanced electrochemical signal generation. The novel architecture simplifies sensor fabrication while improving sensitivity, selectivity, and cost-effectiveness, making it a promising solution for point-of-need water quality monitoring.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/transducers61432.2025.11110442
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-Cost Lead-Ion Imprinted Polymer Membrane Microfluidic Sensor for Selective Trace Lead Monitoring in Water

Ayobami Elisha Oseyemi, Pouya Rezai
1 citations
Analytical Chemistry and Sensors
0.74
article

Low-Cost Lead-Ion Imprinted Polymer Membrane Microfluidic Sensor for Selective Trace Lead Monitoring in Water

Ayobami Elisha Oseyemi, Pouya Rezai
article en
1 citations

Abstract

This study introduces an innovative electrochemical micro fluidic sensor incorporating a stand-alone Lead-ion Imprinted Polymer (Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>+_IIP) membrane for highly selective and trace lead ion detection in water. Unlike conventional sensors, this design embeds the Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>+ - lIP membrane between two in-situ fabricated conductive electrodes within a microfluidic device, enabling direct analyte-membrane interactions for enhanced electrochemical signal generation. The novel architecture simplifies sensor fabrication while improving sensitivity, selectivity, and cost-effectiveness, making it a promising solution for point-of-need water quality monitoring.

York University (CA)
Clean water and sanitation
Openalex Percentile: Top 28%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Low-Cost Lead-Ion Imprinted Polymer Membrane Microfluidic Sensor for Selective Trace Lead Monitoring in Water — Ayobami Elisha Oseyemi, Pouya Rezai · (2025) | TGRS Research Map | TGRS