Femtomolar Detection of Biomarkers by Universal DNA-Based Pendulum Biosensor

This paper reports a universal aptamer-based biosensor which is capable of detecting both small molecules and large biomarkers at femtomole level concentration. The tetrahedral DNA framework (TDF)-tethered pendulant double-stranded DNA (dsDNA) configuration is proposed to obtain a high signal conversion efficiency, and the chronoamperometry detection method is adopted to measure the dynamic response with sub-millisecond accuracy, both of that contribute to such a low LOD. Meanwhile, the TDF-tethered dsDNA structure provides additional benefits of feasible deployment and replaceability, as well as excellent antifouling properties. The proposed TDF-mediated molecular pendulum biosensor holds great potential for biological detecting in vivo, especially for large proteins. Adenosine triphosphate (ATP) and carcinoembryonic antigen (CEA) were employed as test targets to validate the model, with limits of detection (LODs) of 3.96 fM and 0.22 fM, respectively. These values are nearly two orders of magnitude higher than those reported in the current state of the art.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/transducers61432.2025.11111303
Primary Topic
Gene Regulatory Network Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Femtomolar Detection of Biomarkers by Universal DNA-Based Pendulum Biosensor

Xiaoping Li, Songxue Chen, Xiaoran Wang, Dachao Li
Gene Regulatory Network Analysis
article

Femtomolar Detection of Biomarkers by Universal DNA-Based Pendulum Biosensor

Xiaoping Li, Songxue Chen, Xiaoran Wang, Dachao Li
article en

Abstract

This paper reports a universal aptamer-based biosensor which is capable of detecting both small molecules and large biomarkers at femtomole level concentration. The tetrahedral DNA framework (TDF)-tethered pendulant double-stranded DNA (dsDNA) configuration is proposed to obtain a high signal conversion efficiency, and the chronoamperometry detection method is adopted to measure the dynamic response with sub-millisecond accuracy, both of that contribute to such a low LOD. Meanwhile, the TDF-tethered dsDNA structure provides additional benefits of feasible deployment and replaceability, as well as excellent antifouling properties. The proposed TDF-mediated molecular pendulum biosensor holds great potential for biological detecting in vivo, especially for large proteins. Adenosine triphosphate (ATP) and carcinoembryonic antigen (CEA) were employed as test targets to validate the model, with limits of detection (LODs) of 3.96 fM and 0.22 fM, respectively. These values are nearly two orders of magnitude higher than those reported in the current state of the art.

Tianjin University (CN)
Openalex Percentile: Top 81%
Gene Regulatory Network Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.