Optimized Design for Complete ZVS Operation in Phase-Shift Full-Bridge DC-DC Converter with Series-Connected Transformers
This paper proposes an optimized design for complete zero voltage switching (ZVS) operation of the phase-shift full-bridge DC-DC Converter with series-connected transformers. This topology extends the ZVS range at light load, compared with the standard phase-shift full-bridge Buck topology, by exploiting the energy stored in the transformer’s magnetizing inductances. However, at full load, the ZVS condition still requires a suitable leakage inductance, which reduces the effective duty-cycle. A design procedure is proposed that allows a complete ZVS operation without relying on the transformer’s leakage inductance, which can be thus minimized. Experimental results highlight the effectiveness of the proposed design.
Authors
- Giovanni Bonanno (ORCID: https://orcid.org/0000-0002-6779-5579)
- Maria Duca (ORCID: https://orcid.org/0000-0002-2666-6180)
- G. Spiazzi (ORCID: https://orcid.org/0000-0002-6405-5014)
Institutions
- University of Padua (IT)
Publication Details
- Published
- 2025-06-22
- DOI
- https://doi.org/10.1109/compel57166.2025.11121248
- Primary Topic
- Advanced DC-DC Converters
- Type
- article
- Field-Weighted Citation Impact
- 0.00