Experimental Characterization of Switching Losses in SiC-based DAB Converters

Accurate determination of switching losses is critical for the design and operation of soft-switched converters such as the Dual Active Bridge (DAB), particularly at high switching frequencies. In these converters, turn-off loss remains a major contributor to overall switching losses. Additionally, low current at the switching instant can result in only partial zero-voltage switching (ZVS) turn-on, leading to further increases in switching losses. Analytical loss-modeling approaches become increasingly complex due to the presence of nonlinear output capacitance, device parasitics, and printed-circuit-board (PCB) layout effects. This paper presents an experimental methodology to accurately characterize switching losses, including turn-off and partial ZVS turn-on losses, across various operating modes of the DAB converter. Using the actual converter setup, the necessary equivalent circuits are identified for loss characterization across different DAB operating modes. The proposed methodology is validated using SPICE-based simulations and experiments conducted on a 40kW SiC-based DAB hardware prototype.

Authors

Institutions

Publication Details

Published
2025-06-22
DOI
https://doi.org/10.1109/compel57166.2025.11121239
Citations
1
Primary Topic
Silicon Carbide Semiconductor Technologies
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Characterization of Switching Losses in SiC-based DAB Converters

Dragan Maksimović, Ashwini Kumar Dubey, Sayan Paul
1 citations
Silicon Carbide Semiconductor Technologies
0.73
article

Experimental Characterization of Switching Losses in SiC-based DAB Converters

Dragan Maksimović, Ashwini Kumar Dubey, Sayan Paul
article en
1 citations

Abstract

Accurate determination of switching losses is critical for the design and operation of soft-switched converters such as the Dual Active Bridge (DAB), particularly at high switching frequencies. In these converters, turn-off loss remains a major contributor to overall switching losses. Additionally, low current at the switching instant can result in only partial zero-voltage switching (ZVS) turn-on, leading to further increases in switching losses. Analytical loss-modeling approaches become increasingly complex due to the presence of nonlinear output capacitance, device parasitics, and printed-circuit-board (PCB) layout effects. This paper presents an experimental methodology to accurately characterize switching losses, including turn-off and partial ZVS turn-on losses, across various operating modes of the DAB converter. Using the actual converter setup, the necessary equivalent circuits are identified for loss characterization across different DAB operating modes. The proposed methodology is validated using SPICE-based simulations and experiments conducted on a 40kW SiC-based DAB hardware prototype.

Colorado Power Electronics (United States) (US)
Affordable and clean energy
Openalex Percentile: Top 25%
Silicon Carbide Semiconductor Technologies
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Characterization of Switching Losses in SiC-based DAB Converters — Dragan Maksimović, Ashwini Kumar Dubey, et al. · (2025) | TGRS Research Map | TGRS