A 2.3 mW 1 MHz digitally isolated hysteretic current control circuit with shunt-based current sense amplifier
Hysteretic current control (HCC) of the inductor current in switched-mode power converters enables fast and direct control and requires high bandwidth isolated current sensing. However, analog-isolated Hall or TMR sensors consume a high power (typ.: 15mW at 1.5MHz). This work presents a digitally isolated HCC circuit using a shunt resistor, differential amplifier and two comparators with selectable reference values. A 1 MHz bandwidth HCC circuit was built and applied to a half-bridge converter, consuming only 2.3mW during operation (from which 1mW are from an isolated 5V power supply).
Authors
- Stefan Mönch (ORCID: https://orcid.org/0000-0002-5095-8781)
- Adrian Söllner
- Julius Öhrlein
- Ines Bennour
Institutions
- University of Stuttgart (DE)
Publication Details
- Published
- 2025-06-22
- DOI
- https://doi.org/10.1109/compel57166.2025.11121242
- Primary Topic
- Magnetic Properties and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00