Voltage Stability and Support in Wind Farm Integrated LCC-HVDC Systems During FRT

Wind generation is required to provide dynamic voltage support (DVS) during fault ride-through (FRT) to enhance system voltage stability. However, DVS causes the FRT behavior of wind generation to be segmented, and its impact on voltage stability in the wind farm (WF) integrated linecommutated converter-based high-voltage direct current (LCCHVDC) sending-end system remains unclear. To achieve a quantitative analysis to this gap, a novel quasi-static piecewise model for the sending-end system is developed, in which the segmented FRT behavior of WF is fully incorporated. Beyond the well-known saddle-node bifurcation (SNB), a new FRT-induced nonsmooth bifurcation (FRTNB), is identified. The influence of WF and the LCC-HVDC system on both SNB-related and FRTNBrelated voltage stability is thoroughly analyzed. Based on the acquired insights, a control strategy is proposed for the LCCHVDC system to proactively utilize its DVS capability, which is adaptive to the segmented FRT behavior of WF and can effectively enhance system voltage stability without requiring knowledge of grid parameters. Dynamic simulations validate the theoretical analysis and the effectiveness of the proposed method under both voltage sag and swell conditions

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Systems
Published
2025-08-19
DOI
https://doi.org/10.1109/tpwrs.2025.3600222
Citations
4
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
2.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Voltage Stability and Support in Wind Farm Integrated LCC-HVDC Systems During FRT

Zixuan Zheng, Xianyong Xiao, Qi Xie, Yifei Guo
4 citations
IEEE Transactions on Power Systems
HVDC Systems and Fault Protection
2.92
article

Voltage Stability and Support in Wind Farm Integrated LCC-HVDC Systems During FRT

Zixuan Zheng, Xianyong Xiao, Qi Xie, Yifei Guo
article en
4 citations

Abstract

Wind generation is required to provide dynamic voltage support (DVS) during fault ride-through (FRT) to enhance system voltage stability. However, DVS causes the FRT behavior of wind generation to be segmented, and its impact on voltage stability in the wind farm (WF) integrated linecommutated converter-based high-voltage direct current (LCCHVDC) sending-end system remains unclear. To achieve a quantitative analysis to this gap, a novel quasi-static piecewise model for the sending-end system is developed, in which the segmented FRT behavior of WF is fully incorporated. Beyond the well-known saddle-node bifurcation (SNB), a new FRT-induced nonsmooth bifurcation (FRTNB), is identified. The influence of WF and the LCC-HVDC system on both SNB-related and FRTNBrelated voltage stability is thoroughly analyzed. Based on the acquired insights, a control strategy is proposed for the LCCHVDC system to proactively utilize its DVS capability, which is adaptive to the segmented FRT behavior of WF and can effectively enhance system voltage stability without requiring knowledge of grid parameters. Dynamic simulations validate the theoretical analysis and the effectiveness of the proposed method under both voltage sag and swell conditions

IEEE Transactions on Power SystemsVol. 41(1)
Shandong University (CN), Sichuan University (CN)
Affordable and clean energy
Openalex Percentile: Top 8%
HVDC Systems and Fault Protection
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.