Constant-Flow Liquid Transfer System for Skin Microperfusion Biosensing Using a Passive Flow Regulator and a Vacuum Chamber

We developed a powerless constant-flow liquid transfer system for wearable skin microperfusion. Previously, we introduced a minimally invasive microperfusion needle capable of collecting and measuring the concentration of biological substances from subepidermal tissue. A liquid transfer system for skin microperfusion must meet several requirements, including a low and stable flow rate, low power consumption, disposability, and compact size. The new system we report here operates without electrical power by utilizing a passive constant-flow regulator in combination with a vacuum chamber. The flow regulator has a simple structure, comprising a polymethyl methacrylate plate with a microchannel, bonded to a silicone rubber film. This regulator successfully maintained a flow rate with fluctuations within ±0.5 μL/min under low suction pressures ranging from 10 to 30 kPa. To evaluate its performance, the liquid transfer system was connected to a sensor-integrated microperfusion needle inserted into porcine skin. Results from continuous liquid transfer experiments demonstrated that the system was capable of maintaining a stable, low flow rate for more than 90 minutes.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2025-08-19
DOI
https://doi.org/10.1109/lsens.2025.3600679
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Constant-Flow Liquid Transfer System for Skin Microperfusion Biosensing Using a Passive Flow Regulator and a Vacuum Chamber

Yoichi Haga, Noriko Tsuruoka, Koyo Kayaba
IEEE Sensors Letters
Innovative Microfluidic and Catalytic Techniques Innovation
article

Constant-Flow Liquid Transfer System for Skin Microperfusion Biosensing Using a Passive Flow Regulator and a Vacuum Chamber

Yoichi Haga, Noriko Tsuruoka, Koyo Kayaba
article en

Abstract

We developed a powerless constant-flow liquid transfer system for wearable skin microperfusion. Previously, we introduced a minimally invasive microperfusion needle capable of collecting and measuring the concentration of biological substances from subepidermal tissue. A liquid transfer system for skin microperfusion must meet several requirements, including a low and stable flow rate, low power consumption, disposability, and compact size. The new system we report here operates without electrical power by utilizing a passive constant-flow regulator in combination with a vacuum chamber. The flow regulator has a simple structure, comprising a polymethyl methacrylate plate with a microchannel, bonded to a silicone rubber film. This regulator successfully maintained a flow rate with fluctuations within ±0.5 μL/min under low suction pressures ranging from 10 to 30 kPa. To evaluate its performance, the liquid transfer system was connected to a sensor-integrated microperfusion needle inserted into porcine skin. Results from continuous liquid transfer experiments demonstrated that the system was capable of maintaining a stable, low flow rate for more than 90 minutes.

IEEE Sensors LettersVol. 9(9)
Tohoku University (JP)
Affordable and clean energy
Openalex Percentile: Top 80%
Innovative Microfluidic and Catalytic Techniques Innovation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.