Assessment of Safety and Functional Outcomes of Arthroscopic Meniscal Repair Surgery Using Surestitch All-Inside Implant

Introduction Meniscal injuries are prevalent in orthopedic practice, affecting a diverse patient population. In recent times, a notable shift has occurred in the treatment approach for meniscal injuries, favoring repair surgery over the traditional method of meniscectomy. Meniscal repair surgery is a crucial intervention to restore knee function and alleviate symptoms, contributing to improved patient quality of life. Therefore, the present study aimed to assess the safety and functional outcomes of the Surestitch all-inside implants in arthroscopic meniscal repair surgery. Methods From July 2020 to July 2022, 51 patients underwent arthroscopic meniscal repair surgery at Sai Nath Hospital, Maharashtra, India. Patient-reported outcomes, including the International Knee Documentation Committee (IKDC) subjective score, Single Assessment Numeric Evaluation (SANE) score, Tegner activity level, and Lysholm knee score, were recorded through telephonic follow-ups. Detailed patient characteristics, diagnoses, and surgery details were retrospectively extracted from medical records. Results The mean age of the recruited patients was 37.75±11.65 years. About 71% of patients were male (n=36/51). Medial meniscal tear was more prevalent than lateral tear (38 vs. eight patients). The remaining five patients had combined medial and lateral meniscal tears. Patient-reported outcomes showed the mean IKDC, Tegner, and Lysholm scores of 87.49±10.21, 6.03±1.38, and 93.45±9.36, respectively. On comparing the mean SANE scores of affected and unaffected contralateral knees, a significant difference in the scores was observed (86.73±15.94 vs. 97.55±6.81, p<0.05). Conclusion Our data suggest favorable and good functional outcomes of the Surestitch all-inside meniscal repair implant in meniscal repair surgery.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-08-19
DOI
https://doi.org/10.7759/cureus.90520
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Safety and Functional Outcomes of Arthroscopic Meniscal Repair Surgery Using Surestitch All-Inside Implant

Janapamala V S Kishore, Suhas Laxman Kamble, Raj Suhas Kamble, Rohan Hajare et al.
Cureus
Knee injuries and reconstruction techniques
article

Assessment of Safety and Functional Outcomes of Arthroscopic Meniscal Repair Surgery Using Surestitch All-Inside Implant

Janapamala V S Kishore, Suhas Laxman Kamble, Raj Suhas Kamble, Rohan Hajare, Dhammapal Bhamare
article en

Abstract

Introduction Meniscal injuries are prevalent in orthopedic practice, affecting a diverse patient population. In recent times, a notable shift has occurred in the treatment approach for meniscal injuries, favoring repair surgery over the traditional method of meniscectomy. Meniscal repair surgery is a crucial intervention to restore knee function and alleviate symptoms, contributing to improved patient quality of life. Therefore, the present study aimed to assess the safety and functional outcomes of the Surestitch all-inside implants in arthroscopic meniscal repair surgery. Methods From July 2020 to July 2022, 51 patients underwent arthroscopic meniscal repair surgery at Sai Nath Hospital, Maharashtra, India. Patient-reported outcomes, including the International Knee Documentation Committee (IKDC) subjective score, Single Assessment Numeric Evaluation (SANE) score, Tegner activity level, and Lysholm knee score, were recorded through telephonic follow-ups. Detailed patient characteristics, diagnoses, and surgery details were retrospectively extracted from medical records. Results The mean age of the recruited patients was 37.75±11.65 years. About 71% of patients were male (n=36/51). Medial meniscal tear was more prevalent than lateral tear (38 vs. eight patients). The remaining five patients had combined medial and lateral meniscal tears. Patient-reported outcomes showed the mean IKDC, Tegner, and Lysholm scores of 87.49±10.21, 6.03±1.38, and 93.45±9.36, respectively. On comparing the mean SANE scores of affected and unaffected contralateral knees, a significant difference in the scores was observed (86.73±15.94 vs. 97.55±6.81, p<0.05). Conclusion Our data suggest favorable and good functional outcomes of the Surestitch all-inside meniscal repair implant in meniscal repair surgery.

CureusVol. 17(8)
Dr. D. Y. Patil Medical College, Hospital and Research Centre (IN), Hospital Universiti Sains Malaysia (MY), Kalam Institute of Health Technology (IN), Indian Institute of Management Visakhapatnam (IN), Dr D Y Patil Dental College & Hospital (IN)
Good health and well-being
Openalex Percentile: Top 65%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.