Multielemental Analysis of Tellurium Dioxide with Sample Matrix Preseparation by Reactive Distillation

A method is proposed for matrix separation from a sample of tellurium dioxide TeO2 as tellurium tetrachloride based on reactive distillation in a flow reactor at 240°C using gaseous chlorine as a chlorination agent. The behavior of 59 impurities is studied, and it was found that As, Au, B, Bi, Cu, Ga, In, Mo, Nb, Pb, Re, Ru, Sb, Se, Sn, Ta, Ti, V, W, and Zn were lost completely or partially, whereas Ag, Al, Ba, Be, Ca, Cd, Ce, Co, Cr, Dy, Er, Eu, Gd, Ir, Hf, Ho, K, La, Li, Lu, Mg, Mn, Na, Nd, Ni, P, Pd, Pr, Pt, Rb, Rh, Sc, Sm, Sr, Tb, Tm, Y, Yb, and Zr were retained in the concentrate by more than 75%. The impurity content of the concentrate was determined by inductively coupled plasma atomic emission spectrometry. Accuracy was confirmed by the spike experiment and by comparison with the results of analyses without preconcentration. The limits of detection are in the range from 2 × 10–8 to 8 × 10–6 wt %, intralaboratory precision is better than 31%.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2025-08-01
DOI
https://doi.org/10.1134/s1061934825700637
Primary Topic
Advanced Semiconductor Detectors and Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multielemental Analysis of Tellurium Dioxide with Sample Matrix Preseparation by Reactive Distillation

Alphiya R. Tsygankova, Tatiana Ya. Guselnikova, V. A. Oshustanova
Journal of Analytical Chemistry
Advanced Semiconductor Detectors and Materials
article

Multielemental Analysis of Tellurium Dioxide with Sample Matrix Preseparation by Reactive Distillation

Alphiya R. Tsygankova, Tatiana Ya. Guselnikova, V. A. Oshustanova
article en

Abstract

A method is proposed for matrix separation from a sample of tellurium dioxide TeO2 as tellurium tetrachloride based on reactive distillation in a flow reactor at 240°C using gaseous chlorine as a chlorination agent. The behavior of 59 impurities is studied, and it was found that As, Au, B, Bi, Cu, Ga, In, Mo, Nb, Pb, Re, Ru, Sb, Se, Sn, Ta, Ti, V, W, and Zn were lost completely or partially, whereas Ag, Al, Ba, Be, Ca, Cd, Ce, Co, Cr, Dy, Er, Eu, Gd, Ir, Hf, Ho, K, La, Li, Lu, Mg, Mn, Na, Nd, Ni, P, Pd, Pr, Pt, Rb, Rh, Sc, Sm, Sr, Tb, Tm, Y, Yb, and Zr were retained in the concentrate by more than 75%. The impurity content of the concentrate was determined by inductively coupled plasma atomic emission spectrometry. Accuracy was confirmed by the spike experiment and by comparison with the results of analyses without preconcentration. The limits of detection are in the range from 2 × 10–8 to 8 × 10–6 wt %, intralaboratory precision is better than 31%.

Journal of Analytical ChemistryVol. 80(8)
Novosibirsk State University (RU), Nikolaev Institute of Inorganic Chemistry (RU)
Openalex Percentile: Top 80%
Advanced Semiconductor Detectors and Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Multielemental Analysis of Tellurium Dioxide with Sample Matrix Preseparation by Reactive Distillation — Alphiya R. Tsygankova, Tatiana Ya. Guselnikova, et al. · Journal of Analytical Chemistry (2025) | TGRS Research Map | TGRS