Determination of Iodine in CsGeI3 by Inductively Coupled Plasma Atomic Emission Spectrometry

An inductively coupled plasma atomic emission spectrometry (ICP–AES) method for the determination of iodine in CsGeI3 perovskite materials has been developed. The method involves microwave digestion with a hydrochloric-nitric acid system (3 : 1) at 120°C for 10 min, followed by analysis using optimized ICP–AES parameters (radio frequency power: 1150 W, cooling gas flow: 12.5 L/min). The linear range of iodine determination was 1.00–60.00% with a determination coefficient (R2 = 0.999). Recovery rates ranged from 98.6 to 102.1%, and the relative standard deviation (n = 11) was ≤3.4%. The method demonstrated high accuracy and precision, validated through analysis of CsGeI3 samples from diverse sources.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2025-08-01
DOI
https://doi.org/10.1134/s1061934825700698
Primary Topic
Perovskite Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Iodine in CsGeI3 by Inductively Coupled Plasma Atomic Emission Spectrometry

Lijiu Zhang, Li Tian, Qing Xu, Haifeng Sun
Journal of Analytical Chemistry
Perovskite Materials and Applications
article

Determination of Iodine in CsGeI3 by Inductively Coupled Plasma Atomic Emission Spectrometry

Lijiu Zhang, Li Tian, Qing Xu, Haifeng Sun
article en

Abstract

An inductively coupled plasma atomic emission spectrometry (ICP–AES) method for the determination of iodine in CsGeI3 perovskite materials has been developed. The method involves microwave digestion with a hydrochloric-nitric acid system (3 : 1) at 120°C for 10 min, followed by analysis using optimized ICP–AES parameters (radio frequency power: 1150 W, cooling gas flow: 12.5 L/min). The linear range of iodine determination was 1.00–60.00% with a determination coefficient (R2 = 0.999). Recovery rates ranged from 98.6 to 102.1%, and the relative standard deviation (n = 11) was ≤3.4%. The method demonstrated high accuracy and precision, validated through analysis of CsGeI3 samples from diverse sources.

Journal of Analytical ChemistryVol. 80(8)
Korea Testing Certification (KR)
Openalex Percentile: Top 80%
Perovskite Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.