Determination of Ethanol in Soft Drinks by Gas Chromatography Using Headspace Single-Drop Microextraction

A simple and a rapid procedure for the gas-chromatographic determination of ethanol in soft drinks is proposed (kvass, grape juice, non-alcoholic beer) based on the headspace microextraction of an analyte into a drop (1 μL) of distilled water located above the surface of the analyzed liquid on the tip of a needle of a standard microsyringe for gas chromatography. The limit of detection for ethanol is (3–6) × 10–5 vol %, the time of a replicate determination, including headspace extraction, does not exceed 5 min. 2-Propanol, not detected in the beverages, is used as an internal standard. The accuracy of the procedure is confirmed by the added–found method, the relative standard deviation does not exceed 7% at the ethanol concentration in the sample 10–2 vol %.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2025-08-01
DOI
https://doi.org/10.1134/s1061934825700625
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Ethanol in Soft Drinks by Gas Chromatography Using Headspace Single-Drop Microextraction

О. В. Родинков, K. N. Davletbaeva
Journal of Analytical Chemistry
Analytical Chemistry and Chromatography
article

Determination of Ethanol in Soft Drinks by Gas Chromatography Using Headspace Single-Drop Microextraction

О. В. Родинков, K. N. Davletbaeva
article en

Abstract

A simple and a rapid procedure for the gas-chromatographic determination of ethanol in soft drinks is proposed (kvass, grape juice, non-alcoholic beer) based on the headspace microextraction of an analyte into a drop (1 μL) of distilled water located above the surface of the analyzed liquid on the tip of a needle of a standard microsyringe for gas chromatography. The limit of detection for ethanol is (3–6) × 10–5 vol %, the time of a replicate determination, including headspace extraction, does not exceed 5 min. 2-Propanol, not detected in the beverages, is used as an internal standard. The accuracy of the procedure is confirmed by the added–found method, the relative standard deviation does not exceed 7% at the ethanol concentration in the sample 10–2 vol %.

Journal of Analytical ChemistryVol. 80(8)
St Petersburg University (RU)
Openalex Percentile: Top 81%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.